NSN: 5915-01-183-6395
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Overall Length
1.031 inches nominal
-
Special Features
pins 7 and 8 are grounded to case; consists of 11 functions
-
Operating Current Rating Per Function In Amps
0.25 5th radio interference
-
Inclosure Type
encased
-
Unthreaded Mounting Hole Diameter
0.128 inches nominal
-
Operating Current Rating Per Function In Amps
0.25 6th radio interference
-
Source Impedance Rating Per Function
50.0 ohms 4th radio interference
-
Operating Temp Range
-55.0/+125.0 deg celsius
-
Overall Height
1.497 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.812 inches nominal
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Operating Voltage Rating And Type Per Function
200.0 volts dc 5th radio interference 5th function
-
Body Height
0.726 inches maximum
-
Source Impedance Rating Per Function
50.0 ohms 5th radio interference
-
Functional Terminal Type And Quantity
1 connector, receptacle input 1st function
-
Overall Width
1.031 inches nominal
-
Operating Voltage Rating And Type Per Function
200.0 volts dc 1st radio interference 1st function
-
Operating Current Rating Per Function In Amps
0.25 3rd radio interference
-
Operating Current Rating Per Function In Amps
0.25 4th radio interference
-
Operating Voltage Rating And Type Per Function
200.0 volts dc 2nd radio interference 2nd function
-
Load Impedance Per Function
50.0 ohms 3rd radio interference
-
Operating Voltage Rating And Type Per Function
200.0 volts dc 6th radio interference 6th function
-
Source Impedance Rating Per Function
50.0 ohms 6th radio interference
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Load Impedance Per Function
50.0 ohms 4th radio interference
-
Mounting Facility Type And Quantity
4 unthreaded hole
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
0.812 inches nominal
-
Operating Voltage Rating And Type Per Function
200.0 volts dc 3rd radio interference 3rd function
-
Maximum Dielectric Withstanding Dc Voltage
200.0 volts at sea level and 200.0 volts at altitude
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Load Impedance Per Function
50.0 ohms 5th radio interference
-
Distance Between Mounting Surface And Lower End
0.632 inches nominal
-
Functional Terminal Type And Quantity
2 pin ground 3rd function
-
Body Outside Diameter
0.562 inches nominal
-
Load Impedance Per Function
50.0 ohms 6th radio interference
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Operating Current Rating Per Function In Amps
0.25 1st radio interference
-
Style Designator
round terminal/terminals on opposite surfaces
-
Operating Voltage Rating And Type Per Function
200.0 volts dc 4th radio interference 4th function
-
Functional Terminal Type And Quantity
11 pin output 2nd function
-
Operating Current Rating Per Function In Amps
0.25 2nd radio interference
-
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference