NSN: 5915-01-189-3177
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Inclosure Type
hermetically sealed
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference
-
Features Provided
nut and washer
-
Overall Length
11.685 inches nominal
-
Operating Current Rating Per Function In Amps
35.0 1st radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 1st radio interference
-
Maximum Voltage Drop Per Function
1.15 volts ac 2nd radio interference
-
Mounting Facility Type And Quantity
4 slot
-
Operating Current Rating Per Function In Amps
35.0 2nd radio interference
-
Nominal Thread Size
0.190 inches
-
Operating Current Rating Per Function In Amps
35.0 3rd radio interference
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 1st radio interference 1st function
-
Body Length
9.970 inches minimum and 10.030 inches maximum
-
Body Material
metal
-
Functional Terminal Type And Quantity
1 connector, receptacle input 1st function
-
Principal Circuitry Type Per Function
inductance-capacitance 2nd radio interference
-
Body Width
7.060 inches maximum
-
Maximum Voltage Drop Per Function
1.15 volts ac 1st radio interference
-
Operating Temp Range
-0.0/+70.0 deg celsius
-
Functional Terminal Type And Quantity
1 threaded stud ground 3rd function
-
Load Impedance Per Function
50.0 ohms 3rd radio interference
-
Body Height
4.000 inches maximum
-
Style Designator
rectangular terminal/terminals on opposite surfaces
-
Vibration Resistance Range In Hertz
+10.0/+500.0
-
Maximum Dielectric Withstanding Dc Voltage
500.0 volts at sea level
-
Mounting Facility Type And Quantity
6 threaded hole
-
Functional Terminal Type And Quantity
3 threaded stud output 2nd function
-
Maximum Voltage Drop Per Function
1.15 volts ac 3rd radio interference
-
Average Life Rating In Hours
10000.0
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 2nd radio interference 2nd function
-
End Item Identification
mk72m15 sdc
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
5.990 inches minimum and 6.010 inches maximum
-
Input Terminal Identification
ms3406d22-22sx
-
Mounting Slot Width
0.250 inches minimum and 0.260 inches maximum
-
Principal Circuitry Type Per Function
inductance-capacitance 3rd radio interference
-
Power Line Frequency Rating Per Function In Hertz
60.0 1st radio interference
-
Input Terminal Manufacturer Code
96906
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 3rd radio interference 3rd function
-
Mounting Facility Screw Thread Series Designator
unf
-
Power Line Frequency Rating Per Function In Hertz
60.0 2nd radio interference
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Power Line Frequency Rating Per Function In Hertz
60.0 3rd radio interference
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Special Features
three filtered functions