NSN: 5915-01-262-1719

Filters and Networks

FILTER,BAND PASS

5915 - Filters and Networks

FILTER,BAND PASS

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Source Impedance Rating Per Function

    50.0 ohms 4th band pass

  • Inclosure Type

    encased

  • Principal Circuitry Type Per Function

    inductance-capacitance 2nd band pass

  • Operating Temp Range

    -46.0/+75.0 deg celsius

  • Precious Material

    silver

  • Frequency Band Width Per Function

    679.00 megahertz 3rd band pass and 681.00 megahertz 3rd band pass

  • Voltage Standing Wave Ratio Per Function

    1.5 1st band pass

  • Unthreaded Mounting Hole Diameter

    0.120 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    2.000 inches nominal

  • Specified Frequencies Of Discrimination Per Function

    660.00 megahertz 3rd band pass and 679.00 megahertz 3rd band pass and 681.00 megahertz 3rd band pass and 700.00 megahertz 3rd band pass

  • Source Impedance Rating Per Function

    50.0 ohms 1st band pass

  • Load Impedance Per Function

    50.0 ohms 3rd band pass

  • Source Impedance Rating Per Function

    50.0 ohms 3rd band pass

  • Overall Width

    3.780 inches nominal

  • Discrimination At Specified Frequencies Per Function In Decibels

    5.0 maximum 4th band pass and 5.0 maximum 4th band pass and 40.0 minimum 4th band pass and 40.0 minimum 4th band pass

  • Voltage Standing Wave Ratio Frequency Limits Per Function

    619.0 hercules no.5599.1 pulses per second and 621.0 hercules no.5599.1 pulses per second

  • Load Impedance Per Function

    50.0 ohms 2nd band pass

  • Specified Frequencies Of Discrimination Per Function

    659.00 megahertz 2nd band pass and 640.00 megahertz 2nd band pass and 661.00 megahertz 2nd band pass and 680.00 megahertz 2nd band pass

  • Voltage Standing Wave Ratio Frequency Limits Per Function

    659.0 hercules no.5599.1 two phase to two phase and 661.0 hercules no.5599.1 two phase to two phase

  • Discrimination At Specified Frequencies Per Function In Decibels

    5.0 maximum 1st band pass and 40.0 minimum 1st band pass and 5.0 maximum 1st band pass and 40.0 minimum 1st band pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    5.0 1st band pass

  • Functional Terminal Type And Quantity

    4 pin input 1st function

  • Voltage Standing Wave Ratio Per Function

    1.5 2nd band pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    5.0 2nd band pass

  • Overall Height

    0.380 inches nominal

  • Principal Circuitry Type Per Function

    inductance-capacitance 3rd band pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    5.0 3rd band pass

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.520 inches nominal

  • Style Designator

    rectangular terminal/terminals on opposite surfaces

  • Insertion Loss At Reference Frequency Per Function In Decibels

    5.0 4th band pass

  • Voltage Standing Wave Ratio Frequency Limits Per Function

    679.0 hercules no.5599.1 two phase to three phase and 681.0 hercules no.5599.1 two phase to three phase

  • Voltage Standing Wave Ratio Per Function

    1.5 3rd band pass

  • Specified Frequencies Of Discrimination Per Function

    619.00 megahertz 1st band pass and 600.00 megahertz 1st band pass and 621.00 megahertz 1st band pass and 640.00 megahertz 1st band pass

  • Body Length

    1.320 inches nominal

  • Load Impedance Per Function

    50.0 ohms 4th band pass

  • Functional Terminal Type And Quantity

    4 pin output 2nd function

  • Average Life Rating In Hours

    10000.0

  • Reference Frequency Per Function

    660.0 hercules no.5599.1 two phase to two phase

  • Voltage Standing Wave Ratio Frequency Limits Per Function

    639.0 hercules no.5599.1 hertz and 641.0 hercules no.5599.1 hertz

  • Reference Frequency Per Function

    680.0 hercules no.5599.1 two phase to three phase

  • Discrimination At Specified Frequencies Per Function In Decibels

    5.0 maximum 3rd band pass and 5.0 maximum 3rd band pass and 40.0 minimum 3rd band pass and 40.0 minimum 3rd band pass

  • Frequency Band Width Per Function

    619.00 megahertz 1st band pass and 621.00 megahertz 1st band pass

  • Principal Circuitry Type Per Function

    inductance-capacitance 1st band pass

  • Overall Length

    1.720 inches nominal

  • Precious Material And Location

    terminal surfaces silver

  • Frequency Band Width Per Function

    659.00 megahertz 2nd band pass and 661.00 megahertz 2nd band pass

  • Source Impedance Rating Per Function

    50.0 ohms 2nd band pass

  • Frequency Band Width Per Function

    639.00 megahertz 4th band pass and 641.00 megahertz 4th band pass

  • Body Material

    aluminum

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Body Width

    3.500 inches nominal

  • Voltage Standing Wave Ratio Per Function

    1.5 4th band pass

  • Specified Frequencies Of Discrimination Per Function

    620.00 megahertz 4th band pass and 641.00 megahertz 4th band pass and 639.00 megahertz 4th band pass and 660.00 megahertz 4th band pass

  • Reference Frequency Per Function

    620.0 hercules no.5599.1 pulses per second

  • Discrimination At Specified Frequencies Per Function In Decibels

    5.0 maximum 2nd band pass and 40.0 minimum 2nd band pass and 5.0 maximum 2nd band pass and 40.0 minimum 2nd band pass

  • Principal Circuitry Type Per Function

    inductance-capacitance 4th band pass

  • Reference Frequency Per Function

    640.0 hercules no.5599.1 hertz

  • Load Impedance Per Function

    50.0 ohms 1st band pass

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...