Technical Characteristics

  • Operating Current Rating Per Function In Amps

    5.0 3rd radio interference

  • Inclosure Type

    encased

  • Operating Current Rating Per Function In Amps

    5.0 4th radio interference

  • Load Impedance Per Function

    50.0 ohms 3rd radio interference

  • Nominal Thread Size

    1.062 inches

  • Source Impedance Rating Per Function

    50.0 ohms 6th radio interference

  • Maximum Dielectric Withstanding Dc Voltage

    500.0 volts at sea level

  • Average Life Rating In Hours

    1000.0

  • Source Impedance Rating Per Function

    50.0 ohms 1st radio interference

  • Overall Length

    0.518 inches nominal

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 1st radio interference 1st function and 200.0 volts dc 1st radio interference 1st function

  • Load Impedance Per Function

    50.0 ohms 4th radio interference

  • Unthreaded Mounting Hole Diameter

    0.123 inches minimum and 0.130 inches maximum

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Principal Circuitry Type Per Function

    inductance-capacitance 3rd radio interference

  • Power Line Frequency Rating Per Function In Hertz

    60.0 1st radio interference

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 3rd radio interference 3rd function and 200.0 volts dc 3rd radio interference 3rd function

  • Operating Current Rating Per Function In Amps

    5.0 1st radio interference

  • Mounting Facility Screw Thread Series Designator

    unef

  • Power Line Frequency Rating Per Function In Hertz

    60.0 2nd radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 2nd radio interference

  • Load Impedance Per Function

    50.0 ohms 5th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    60.0 3rd radio interference

  • Precious Material And Location

    contact surfaces gold

  • Principal Circuitry Type Per Function

    inductance-capacitance 4th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    60.0 4th radio interference

  • Functional Terminal Type And Quantity

    2 friction w/grounding strap and pin ground 3rd function

  • Principal Circuitry Type Per Function

    inductance-capacitance 6th radio interference

  • Operating Current Rating Per Function In Amps

    5.0 5th radio interference

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 4th radio interference 4th function and 200.0 volts dc 4th radio interference 4th function

  • Operating Current Rating Per Function In Amps

    5.0 6th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 4th radio interference

  • Operating Temp Range

    -55.0/+125.0 deg celsius

  • Load Impedance Per Function

    50.0 ohms 2nd radio interference

  • Body Outside Diameter

    0.062 inches maximum

  • Precious Material

    gold

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 5th radio interference 5th function and 200.0 volts dc 5th radio interference 5th function

  • Body Material

    metal

  • Source Impedance Rating Per Function

    50.0 ohms 5th radio interference

  • Functional Terminal Type And Quantity

    1 connector, receptacle input 1st function

  • Principal Circuitry Type Per Function

    inductance-capacitance 2nd radio interference

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 2nd radio interference 2nd function and 200.0 volts dc 2nd radio interference 2nd function

  • Principal Circuitry Type Per Function

    inductance-capacitance 5th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 3rd radio interference

  • Body Surface Treatment

    gold

  • Functional Terminal Type And Quantity

    16 friction w/grounding strap and pin output 2nd function

  • Principal Circuitry Type Per Function

    inductance-capacitance 1st radio interference

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 6th radio interference 6th function and 200.0 volts dc 6th radio interference 6th function

  • Power Line Frequency Rating Per Function In Hertz

    60.0 5th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    60.0 6th radio interference

  • Load Impedance Per Function

    50.0 ohms 6th radio interference

  • Style Designator

    round terminal/terminals on opposite surface

  • Load Impedance Per Function

    50.0 ohms 1st radio interference

  • Operating Current Rating Per Function In Amps

    5.0 2nd radio interference

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...