Technical Characteristics

  • Load Impedance Per Function

    50.0 ohms 3rd radio interference

  • Power Line Frequency Rating Per Function In Hertz

    60.0 2nd radio interference

  • Power Line Frequency Rating Per Function In Hertz

    60.0 4th radio interference

  • Operating Current Rating Per Function In Amps

    15.0 2nd radio interference

  • Operating Current Rating Per Function In Amps

    15.0 3rd radio interference

  • Operating Current Rating Per Function In Amps

    15.0 4th radio interference

  • Maximum Voltage Drop Per Function

    1.2 volts ac 1st radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 2nd radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 3rd radio interference

  • Input Terminal Manufacturer Code

    23939

  • Output Terminal Manufacturer Code

    23939

  • Maximum Temp Rise

    25.0 deg celsius

  • Mounting Facility Screw Thread Series Designator

    unc

  • Mounting Facility Type And Quantity

    10 slot

  • Functional Terminal Type And Quantity

    1 connector, receptacle input

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 1st radio interference

  • Body Material

    metal

  • Style Designator

    1 rectangular terminal/terminals on opposite surfaces

  • Mounting Slot Width

    0.218 inches nominal

  • Body Width

    8.990 inches minimum and 9.010 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    11.245 inches minimum and 11.255 inches maximum

  • Vibration Resistance Range In Hertz

    10.0 to 200.0

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    5.995 inches minimum and 6.005 inches maximum

  • Operating Temp Range

    -40.0 to 52.0 deg celsius

  • Source Impedance Rating Per Function

    50.0 ohms 3rd radio interference

  • Load Impedance Per Function

    50.0 ohms 1st radio interference

  • Overall Length

    11.990 inches minimum and 12.010 inches maximum

  • Overall Height

    2.990 inches minimum and 3.010 inches maximum

  • Overall Width

    11.470 inches minimum and 11.530 inches maximum

  • Body Length

    10.495 inches minimum and 10.505 inches maximum

  • Average Life Rating In Hours

    30000.0

  • Source Impedance Rating Per Function

    50.0 ohms 1st radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 2nd radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 4th radio interference

  • Load Impedance Per Function

    50.0 ohms 2nd radio interference

  • Load Impedance Per Function

    50.0 ohms 4th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    60.0 1st radio interference

  • Power Line Frequency Rating Per Function In Hertz

    60.0 3rd radio interference

  • Operating Current Rating Per Function In Amps

    15.0 1st radio interference

  • Maximum Voltage Drop Per Function

    1.2 volts ac 2nd radio interference

  • Maximum Voltage Drop Per Function

    1.2 volts ac 3rd radio interference

  • Maximum Voltage Drop Per Function

    1.2 volts ac 4th radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 1st radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 4th radio interference

  • Input Terminal Identification

    sma-receptacle

  • Output Terminal Identification

    sma-receptacle

  • Inclosure Type

    hermetically sealed

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Functional Terminal Type And Quantity

    1 connector, receptacle output

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 2nd radio interference

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 3rd radio interference

  • Operating Voltage Rating And Type Per Function

    120.0 volts ac 4th radio interference

  • Nominal Thread Size

    0.164 inches

  • Maximum Dielectric Withstanding Dc Voltage

    1.0 kilovolts at sea level

  • Body Surface Treatment

    tin

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...