NSN: 5915-01-294-2272
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Overall Length
5.660 inches minimum and 5.840 inches maximum
-
Overall Height
3.410 inches minimum and 3.590 inches maximum
-
Body Width
2.970 inches minimum and 3.030 inches maximum
-
Body Height
2.720 inches minimum and 2.780 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
2.490 inches minimum and 2.510 inches maximum
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference .
-
Load Impedance Per Function
50.0 ohms 1st radio interference .
-
Body Length
4.970 inches minimum and 5.030 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.490 inches minimum and 4.510 inches maximum
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference .
-
Load Impedance Per Function
50.0 ohms 2nd radio interference .
-
Power Line Frequency Rating Per Function In Hertz
60.0 1st radio interference .
-
Power Line Frequency Rating Per Function In Hertz
60.0 2nd radio interference .
-
Operating Current Rating Per Function In Amps
20.0 1st radio interference .
-
Principal Circuitry Type Per Function
inductance-capacitance 2nd radio interference
-
Functional Terminal Type And Quantity
2 threaded stud input .
-
Style Designator
27 rectangular terminal/terminals on two surfaces
-
Body Material
metal
-
Nominal Thread Size
0.164 inches
-
Operating Voltage Rating And Type Per Function
208.0 volts ac 2nd radio interference .
-
Operating Voltage Rating And Type Per Function
208.0 volts ac 1st radio interference .
-
Functional Terminal Type And Quantity
2 threaded stud output .
-
Functional Terminal Type And Quantity
2 threaded stud ground .
-
Mounting Facility Type And Quantity
4 threaded hole
-
Inclosure Type
encased
-
Mounting Facility Screw Thread Series Designator
unc
-
Principal Circuitry Type Per Function
inductance-capacitance 1st radio interference
-
Operating Current Rating Per Function In Amps
20.0 2nd radio interference .