NSN: 5915-01-302-7802

Filters and Networks

FILTER,BAND PASS

5915 - Filters and Networks

FILTER,BAND PASS

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Overall Length

    5.170 inches minimum and 5.350 inches maximum

  • Body Length

    4.370 inches minimum and 4.430 inches maximum

  • Body Height

    0.590 inches minimum and 0.650 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    4.190 inches minimum and 4.210 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.410 inches minimum and 0.430 inches maximum

  • Operating Temp Range

    -55.0 to 85.0 deg celsius

  • End Item Identification

    an/mst-t1v

  • Reference Frequency Per Function

    7.05 gigahertz blank

  • Load Impedance Per Function

    50.0 ohms blank

  • Input Terminal Identification

    sma-receptacle

  • Output Terminal Identification

    sma-receptacle

  • Voltage Standing Wave Ratio Per Function

    1.5 blank

  • Inclosure Type

    encased

  • Specified Frequencies Of Discrimination Per Function

    6.49 gigahertz blank and 6.70 gigahertz blank and 7.40 gigahertz blank and 7.61 gigahertz blank

  • Nominal Thread Size

    0.112 inches

  • Body Material

    metal

  • Frequency Band Width Per Function

    6.70 gigahertz blank and 7.40 gigahertz blank

  • Style Designator

    5 rectangular terminal/terminals on opposite surfaces

  • Body Width

    0.590 inches minimum and 0.650 inches maximum

  • Vibration Resistance Range In Hertz

    10.0 to 2000.0

  • Source Impedance Rating Per Function

    50.0 ohms blank

  • Principal Circuitry Type Per Function

    inductance-capacitance blank

  • Input Terminal Manufacturer Code

    50140

  • Output Terminal Manufacturer Code

    50140

  • Average Power Rating Per Function

    300.0 watts blank

  • Mounting Facility Screw Thread Series Designator

    unc

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 blank

  • Functional Terminal Type And Quantity

    1 connector, receptacle input

  • Functional Terminal Type And Quantity

    1 connector, receptacle output

  • Maximum Dielectric Withstanding Ac Rms Voltage

    700.0 volts at sea level

  • Discrimination At Specified Frequencies Per Function In Decibels

    65.0 minimum blank and 3.0 maximum blank and 3.0 maximum blank and 65.0 minimum blank

  • Voltage Standing Wave Ratio Frequency Limits Per Function

    6.7 gigahertz blank and 7.4 gigahertz blank

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...