NSN: 5915-01-305-5128

Filters and Networks

FILTER,LOW PASS

5915 - Filters and Networks

FILTER,LOW PASS

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Specified Frequencies Of Discrimination Per Function

    700.00 megahertz 2nd low pass and 1.00 gigahertz 2nd low pass and 1.40 gigahertz 2nd low pass and 2.80 gigahertz 2nd low pass

  • Nominal Thread Size

    0.164 inches

  • Frequency Band Width Per Function

    1.00 gigahertz 3rd low pass and 1.40 gigahertz 3rd low pass

  • Frequency Band Width Per Function

    500.00 megahertz 1st low pass and 700.00 megahertz 1st low pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    37.0 minimum 4th low pass and 3.0 maximum 4th low pass

  • Voltage Standing Wave Ratio Frequency Limits Per Function

    1.4 gigahertz 4th low pass and 2.0 gigahertz 4th low pass

  • Voltage Standing Wave Ratio Frequency Limits Per Function

    500.0 megahertz 1st low pass and 700.0 megahertz 1st low pass

  • Style Designator

    5 rectangular terminal/terminals on opposite surfaces

  • Body Length

    7.140 inches minimum and 7.740 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    8.365 inches minimum and 8.385 inches maximum

  • Vibration Resistance Range In Hertz

    5.0 to 55.0

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    4.740 inches minimum and 4.760 inches maximum

  • Operating Temp Range

    10.0 to 60.0 deg celsius

  • Reference Frequency Per Function

    1.2 gigahertz 3rd low pass

  • Reference Frequency Per Function

    1.7 gigahertz 4th low pass

  • Reference Frequency Per Function

    600.0 megahertz 1st low pass

  • Load Impedance Per Function

    50.0 ohms 3rd low pass

  • Load Impedance Per Function

    50.0 ohms 4th low pass

  • Principal Circuitry Type Per Function

    inductance-capacitance 2nd low pass

  • Principal Circuitry Type Per Function

    inductance-capacitance 3rd low pass

  • Output Terminal Manufacturer Code

    60483

  • Output Terminal Identification

    sma-receptacle

  • Voltage Standing Wave Ratio Per Function

    2.0 1st low pass

  • Voltage Standing Wave Ratio Per Function

    2.0 3rd low pass

  • Voltage Standing Wave Ratio Per Function

    2.0 4th low pass

  • Mounting Facility Screw Thread Series Designator

    unc

  • Inclosure Type

    encased

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Features Provided

    shock resistant

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 1st low pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 3rd low pass

  • Functional Terminal Type And Quantity

    2 connector, receptacle input

  • Functional Terminal Type And Quantity

    2 connector, receptacle output

  • Specified Frequencies Of Discrimination Per Function

    1.40 gigahertz 4th low pass and 2.00 gigahertz 4th low pass and 2.80 gigahertz 4th low pass and 5.60 gigahertz 4th low pass

  • Body Material

    metal

  • Frequency Band Width Per Function

    1.40 gigahertz 4th low pass and 2.00 gigahertz 4th low pass

  • Frequency Band Width Per Function

    700.00 megahertz 2nd low pass and 1.00 gigahertz 2nd low pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    37.0 minimum 1st low pass and 3.0 maximum 1st low pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    37.0 minimum 2nd low pass and 3.0 maximum 2nd low pass

  • Discrimination At Specified Frequencies Per Function In Decibels

    37.0 minimum 3rd low pass and 3.0 maximum 3rd low pass

  • Voltage Standing Wave Ratio Frequency Limits Per Function

    1.0 gigahertz 3rd low pass and 1.4 gigahertz 3rd low pass

  • Voltage Standing Wave Ratio Frequency Limits Per Function

    700.0 megahertz 2nd low pass and 1.0 gigahertz 2nd low pass

  • Body Surface Treatment

    nickel

  • Special Features

    consists of four filtered functions

  • Overall Length

    9.330 inches minimum and 9.430 inches maximum

  • Body Width

    2.500 inches maximum

  • Body Height

    1.300 inches maximum

  • Average Life Rating In Hours

    1000.0

  • End Item Identification

    test set,electronic warfare simulator an/alm-234

  • Reference Frequency Per Function

    850.0 megahertz 2nd low pass

  • Source Impedance Rating Per Function

    50.0 ohms 1st low pass

  • Source Impedance Rating Per Function

    50.0 ohms 2nd low pass

  • Source Impedance Rating Per Function

    50.0 ohms 3rd low pass

  • Source Impedance Rating Per Function

    50.0 ohms 4th low pass

  • Load Impedance Per Function

    50.0 ohms 1st low pass

  • Load Impedance Per Function

    50.0 ohms 2nd low pass

  • Principal Circuitry Type Per Function

    inductance-capacitance 1st low pass

  • Principal Circuitry Type Per Function

    inductance-capacitance 4th low pass

  • Input Terminal Manufacturer Code

    60483

  • Input Terminal Identification

    sma-receptacle

  • Voltage Standing Wave Ratio Per Function

    2.0 2nd low pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 2nd low pass

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.0 4th low pass

  • Specified Frequencies Of Discrimination Per Function

    1.00 gigahertz 3rd low pass and 1.40 gigahertz 3rd low pass and 2.00 gigahertz 3rd low pass and 4.00 gigahertz 3rd low pass

  • Specified Frequencies Of Discrimination Per Function

    500.00 megahertz 1st low pass and 700.00 megahertz 1st low pass and 1.00 gigahertz 1st low pass and 2.00 gigahertz 1st low pass

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...