NSN: 5915-01-315-2375
Filters and Networks
FILTER,BAND PASS-BAND SUPPRESSION
FILTER,BAND PASS-BAND SUPPRESSION
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Length
5.000 inches nominal
-
Reference Frequency Per Function
1835.0 megahertz 4th band suppression .
-
Reference Frequency Per Function
305.0 megahertz 2nd band pass .
-
Source Impedance Rating Per Function
50.0 ohms 1st band pass .
-
Source Impedance Rating Per Function
50.0 ohms 2nd band pass .
-
Source Impedance Rating Per Function
50.0 ohms 3rd band suppression .
-
Load Impedance Per Function
50.0 ohms 1st band pass .
-
Load Impedance Per Function
50.0 ohms 2nd band pass .
-
Load Impedance Per Function
50.0 ohms 4th band suppression .
-
Voltage Standing Wave Ratio Per Function
1.2 1st band pass .
-
Voltage Standing Wave Ratio Per Function
1.2 3rd band suppression .
-
Inclosure Type
encased
-
Insertion Loss At Reference Frequency Per Function In Decibels
0.5 2nd band pass .
-
Insertion Loss At Reference Frequency Per Function In Decibels
35.0 3rd band suppression .
-
Functional Terminal Type And Quantity
1 connector, receptacle input and 1 connector, receptacle output
-
Frequency Band Width Per Function
0.47 gigahertz 4th band suppression and 3.20 gigahertz 4th band suppression .
-
Frequency Band Width Per Function
225.00 megahertz 3rd band suppression and 260.00 megahertz 3rd band suppression
-
Frequency Band Width Per Function
260.00 megahertz 2nd band pass and 350.00 megahertz 2nd band pass .
-
Criticality Code Justification
feat
-
Special Features
electro static sensitive
-
Style Designator
44 rectangular terminal/terminals on one surface
-
Overall Height
2.990 inches nominal
-
Body Height
2.500 inches nominal
-
Operating Temp Range
-55.0/+100.0 deg celsius
-
End Item Identification
alt-32 band trns b52gh
-
Reference Frequency Per Function
177.5 megahertz 1st band pass .
-
Reference Frequency Per Function
243.0 megahertz 3rd band suppression .
-
Source Impedance Rating Per Function
50.0 ohms 4th band suppression .
-
Load Impedance Per Function
50.0 ohms 3rd band suppression .
-
Voltage Standing Wave Ratio Per Function
1.2 2nd band pass .
-
Voltage Standing Wave Ratio Per Function
1.2 4th band suppression .
-
Mounting Facility Type And Quantity
4 threaded hole
-
Insertion Loss At Reference Frequency Per Function In Decibels
0.5 1st band pass .
-
Insertion Loss At Reference Frequency Per Function In Decibels
25.0 4th band suppression .
-
~1
.
-
Frequency Band Width Per Function
130.00 megahertz 1st band pass and 225.00 megahertz 1st band pass .