Technical Characteristics

  • Body Length

    1.650 inches nominal

  • Body Width

    0.490 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.530 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.370 inches nominal

  • Source Impedance Rating Per Function

    50.0 ohms blank

  • Load Impedance Per Function

    50.0 ohms blank

  • Input Terminal Identification

    sma-receptacle

  • Inclosure Type

    encased

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Insertion Loss At Reference Frequency Per Function In Decibels

    3.5 blank

  • ~1

    990.00 megahertz blank

  • Specified Frequencies Of Discrimination Per Function

    810.00 megahertz blank and 895.00 megahertz blank and 905.00 megahertz blank and

  • Body Surface Treatment

    nickel

  • Overall Length

    2.410 inches nominal

  • Body Height

    0.390 inches nominal

  • Operating Temp Range

    +0.0/+50.0 deg celsius

  • End Item Identification

    training set,countermeasures signals an/msr-t4

  • Reference Frequency Per Function

    900.0 megahertz blank

  • Principal Circuitry Type Per Function

    inductance-capacitance blank

  • Input Terminal Manufacturer Code

    56216

  • Output Terminal Manufacturer Code

    56216

  • Output Terminal Identification

    sma-receptacle

  • Voltage Standing Wave Ratio Per Function

    1.5 blank

  • Mounting Facility Screw Thread Series Designator

    unf

  • Functional Terminal Type And Quantity

    1 connector, receptacle input .

  • Functional Terminal Type And Quantity

    1 connector, receptacle output .

  • Nominal Thread Size

    0.060 inches

  • Body Material

    aluminum

  • Frequency Band Width Per Function

    895.00 megahertz blank and 905.00 megahertz blank

  • Discrimination At Specified Frequencies Per Function In Decibels

    1.0 minimum blank and 60.0 maximum blank

  • Voltage Standing Wave Ratio Frequency Limits Per Function

    895.0 megahertz blank and 905.0 megahertz blank

  • Style Designator

    5 rectangular terminal/terminals on opposite surfaces

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...