NSN: 5915-01-319-2325
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Style Designator
5 rectangular terminal/terminals on opposite surfaces
-
Special Features
five filtered functions
-
Body Material
metal
-
Operating Voltage Rating And Type Per Function
250.0 volts ac 3rd radio interference .
-
Operating Voltage Rating And Type Per Function
250.0 volts ac 2nd radio interference .
-
Operating Voltage Rating And Type Per Function
250.0 volts ac 1st radio interference .
-
Mounting Facility Type And Quantity
8 threaded stud
-
Mounting Facility Screw Thread Series Designator
unc
-
Principal Circuitry Type Per Function
inductance-capacitance 5th radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 3rd radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 2nd radio interference
-
Operating Current Rating Per Function In Amps
30.0 5th radio interference .
-
Operating Current Rating Per Function In Amps
30.0 1st radio interference .
-
Power Line Frequency Rating Per Function In Hertz
60.0 2nd radio interference .
-
Power Line Frequency Rating Per Function In Hertz
60.0 1st radio interference .
-
Load Impedance Per Function
50.0 ohms 2nd radio interference .
-
Load Impedance Per Function
50.0 ohms 1st radio interference .
-
Source Impedance Rating Per Function
50.0 ohms 5th radio interference .
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference .
-
Body Height
2.500 inches nominal
-
Body Width
5.500 inches nominal
-
Nominal Thread Size
0.164 inches
-
Operating Voltage Rating And Type Per Function
250.0 volts ac 5th radio interference .
-
Operating Voltage Rating And Type Per Function
250.0 volts ac 4th radio interference .
-
Inclosure Type
hermetically sealed
-
Principal Circuitry Type Per Function
inductance-capacitance 4th radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 1st radio interference
-
Operating Current Rating Per Function In Amps
30.0 4th radio interference .
-
Operating Current Rating Per Function In Amps
30.0 3rd radio interference .
-
Operating Current Rating Per Function In Amps
30.0 2nd radio interference .
-
Power Line Frequency Rating Per Function In Hertz
60.0 5th radio interference .
-
Power Line Frequency Rating Per Function In Hertz
60.0 4th radio interference .
-
Power Line Frequency Rating Per Function In Hertz
60.0 3rd radio interference .
-
Load Impedance Per Function
50.0 ohms 5th radio interference .
-
Load Impedance Per Function
50.0 ohms 4th radio interference .
-
Load Impedance Per Function
50.0 ohms 3rd radio interference .
-
Source Impedance Rating Per Function
50.0 ohms 4th radio interference .
-
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference .
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference .
-
Operating Temp Range
-55.0/+85.0 deg celsius
-
Body Length
8.000 inches nominal
-
Overall Length
18.000 inches nominal