Technical Characteristics

  • Maximum Temp Rise

    25.0 deg celsius

  • Operating Current Rating Per Function In Amps

    5.0 3rd radio interference

  • Output Terminal Manufacturer Code

    59610

  • Operating Voltage Rating And Type Per Function

    800.0 volts dc 1st radio interference 1st function

  • Operating Current Rating Per Function In Amps

    5.0 4th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 2nd radio interference

  • Overall Length

    2.187 inches nominal

  • Principal Circuitry Type Per Function

    inductance-capacitance 6th radio interference

  • Operating Current Rating Per Function In Amps

    5.0 5th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 3rd radio interference

  • Input Terminal Manufacturer Code

    59610

  • Operating Current Rating Per Function In Amps

    5.0 6th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 4th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 4th radio interference

  • ~1

    interference 1st function and 250.0 volts ac 5th radio

  • ~1

    2nd radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 1st radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 1st radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 3rd radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 5th radio interference

  • Operating Current Rating Per Function In Amps

    5.0 2nd radio interference

  • Load Impedance Per Function

    50.0 ohms 1st radio interference

  • Maximum Voltage Drop Per Function

    8.0 volts dc 6th radio interference

  • Body Surface Treatment

    cadmium

  • Input Terminal Identification

    mil-c-26482

  • Load Impedance Per Function

    50.0 ohms 6th radio interference

  • Maximum Voltage Drop Per Function

    8.0 volts dc 5th radio interference

  • Maximum Voltage Drop Per Function

    8.0 volts dc 4th radio interference

  • Output Terminal Identification

    mil-c-26482

  • Maximum Voltage Drop Per Function

    8.0 volts dc 3rd radio interference

  • Inclosure Type

    hermetically sealed

  • Principal Circuitry Type Per Function

    inductance-capacitance 4th radio interference

  • Special Features

    ten filtered functions with 12-10py type insert arrangement

  • Precious Material And Location

    contact surfaces gold

  • Load Impedance Per Function

    50.0 ohms 5th radio interference

  • Functional Terminal Type And Quantity

    10 friction w/grounding strap and pin input-output

  • Source Impedance Rating Per Function

    50.0 ohms 2nd radio interference

  • Features Provided

    moisture resistant and shock resistant

  • Maximum Voltage Drop Per Function

    8.0 volts dc 1st radio interference

  • Operating Current Rating Per Function In Amps

    5.0 1st radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 3rd radio interference

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Body Material

    aluminum

  • Load Impedance Per Function

    50.0 ohms 4th radio interference

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.750 inches nominal

  • Maximum Dielectric Withstanding Dc Voltage

    1.2 kilovolts at sea level

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.750 inches nominal

  • Source Impedance Rating Per Function

    50.0 ohms 1st radio interference

  • Style Designator

    filter connector

  • Source Impedance Rating Per Function

    50.0 ohms 6th radio interference

  • Load Impedance Per Function

    50.0 ohms 3rd radio interference

  • Operating Voltage Rating And Type Per Function

    800.0 volts dc 6th radio interference 6th function

  • Overall Height

    2.405 inches nominal

  • Operating Voltage Rating And Type Per Function

    800.0 volts dc 5th radio interference 5th function

  • Unthreaded Mounting Hole Diameter

    0.125 inches nominal

  • Operating Voltage Rating And Type Per Function

    800.0 volts dc 4th radio interference 4th function

  • Principal Circuitry Type Per Function

    inductance-capacitance 2nd radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 5th radio interference

  • Operating Voltage Rating And Type Per Function

    800.0 volts dc 3rd radio interference 3rd function

  • Precious Material

    gold

  • Overall Width

    2.405 inches nominal

  • Power Line Frequency Rating Per Function In Hertz

    400.0 6th radio interference

  • Load Impedance Per Function

    50.0 ohms 2nd radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 5th radio interference

  • Operating Temp Range

    -55.0/+125.0 deg celsius

  • Maximum Voltage Drop Per Function

    2.5 volts ac 4th radio interference and 2.5 volts ac 3rd radio interference and 2.5 volts ac 1st radio interference and 2.5 volts ac 2nd radio interference and 2.5 volts ac 6th radio interference and 2.5 volts ac 5th radio interference and 8.0 volts dc

  • Operating Voltage Rating And Type Per Function

    250.0 volts ac 3rd radio interference 3rd function and 250.0 volts ac 2nd radio interference 2nd function and 250.0 volts ac 6th radio interference 6th function and 250.0 volts ac 4th radio interference 4th function and 250.0 volts ac 1st radio

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...