Technical Characteristics

  • Overall Height

    1.020 inches minimum and 1.040 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    0.772 inches nominal

  • Load Impedance Per Function

    50.0 ohms 4th radio interference

  • Body Material

    aluminum

  • Principal Circuitry Type Per Function

    inductance-capacitance 3rd radio interference

  • Input Terminal Manufacturer Code

    73030

  • Operating Voltage Rating And Type Per Function

    200.0 volts dc 3rd radio interference 3rd function

  • Operating Current Rating Per Function In Amps

    5.0 1st radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 2nd radio interference

  • Load Impedance Per Function

    50.0 ohms 5th radio interference

  • Overall Width

    1.020 inches minimum and 1.040 inches maximum

  • Overall Length

    1.685 inches nominal

  • Precious Material And Location

    contact surfaces gold

  • Principal Circuitry Type Per Function

    inductance-capacitance 4th radio interference

  • Inclosure Type

    hermetically sealed

  • Average Life Rating In Hours

    500.0

  • Load Impedance Per Function

    50.0 ohms 6th radio interference

  • Body Surface Treatment

    cadmium

  • Full Load Minimum Insertion Loss At Specified Frequency In Decibels

    40.0 and 17.0 and 2.5 and 2.5 and 2.5 and 40.0

  • Load Impedance Per Function

    50.0 ohms 1st radio interference

  • Operating Current Rating Per Function In Amps

    5.0 5th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 3rd radio interference

  • Operating Current Rating Per Function In Amps

    5.0 6th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 4th radio interference

  • Power Line Frequency Rating Per Function In Hertz

    400.0 4th radio interference

  • Operating Temp Range

    -55.0/+125.0 deg celsius

  • Power Line Frequency Rating Per Function In Hertz

    400.0 5th radio interference

  • Load Impedance Per Function

    50.0 ohms 2nd radio interference

  • ~1

    interference 3rd function and 125.0 volts ac 6th radio

  • ~1

    dc 2nd radio interference

  • Operating Current Rating Per Function In Amps

    5.0 2nd radio interference

  • Operating Voltage Rating And Type Per Function

    200.0 volts dc 4th radio interference 4th function

  • Principal Circuitry Type Per Function

    inductance-capacitance 5th radio interference

  • Source Impedance Rating Per Function

    50.0 ohms 3rd radio interference

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.772 inches nominal

  • Power Line Frequency Rating Per Function In Hertz

    400.0 1st radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 1st radio interference

  • Maximum Temp Rise

    25.0 deg celsius

  • Operating Current Rating Per Function In Amps

    5.0 3rd radio interference

  • Maximum Voltage Drop Per Function

    2.0 volts dc 1st radio interference

  • Operating Current Rating Per Function In Amps

    5.0 4th radio interference

  • Mounting Facility Type And Quantity

    4 slot

  • Power Line Frequency Rating Per Function In Hertz

    400.0 2nd radio interference

  • Features Provided

    fungus resistant and moisture resistant

  • Principal Circuitry Type Per Function

    inductance-capacitance 6th radio interference

  • Operating Voltage Rating And Type Per Function

    125.0 volts ac 5th radio interference 5th function and 125.0 volts ac 1st radio interference 1st function and 125.0 volts ac 4th radio interference 4th function and 125.0 volts ac 2nd radio interference 2nd function and 125.0 volts ac 3rd radio

  • Maximum Voltage Drop Per Function

    1.25 volts ac 6th radio interference and 1.25 volts ac 3rd radio interference and 1.25 volts ac 1st radio interference and 1.25 volts ac 2nd radio interference and 1.25 volts ac 4th radio interference and 1.25 volts ac 5th radio interference and 2.0 volts

  • Operating Voltage Rating And Type Per Function

    200.0 volts dc 5th radio interference 5th function

  • Criticality Code Justification

    feat

  • Power Line Frequency Rating Per Function In Hertz

    400.0 6th radio interference

  • Maximum Voltage Drop Per Function

    2.0 volts dc 3rd radio interference

  • Output Terminal Identification

    sma-receptacle

  • Maximum Voltage Drop Per Function

    2.0 volts dc 4th radio interference

  • Mounting Slot Width

    0.122 inches minimum and 0.136 inches maximum

  • Maximum Voltage Drop Per Function

    2.0 volts dc 5th radio interference

  • Maximum Voltage Drop Per Function

    2.0 volts dc 6th radio interference

  • Precious Material

    gold

  • Source Impedance Rating Per Function

    50.0 ohms 5th radio interference

  • Principal Circuitry Type Per Function

    inductance-capacitance 2nd radio interference

  • Functional Terminal Type And Quantity

    6 friction w/grounding strap and pin input-output

  • Operating Voltage Rating And Type Per Function

    200.0 volts dc 2nd radio interference 2nd function

  • Input Terminal Identification

    sma connector plug

  • Load Impedance Per Function

    50.0 ohms 3rd radio interference

  • Full Load Insertion Loss Frequencies In Megahertz

    100.0 and 10.0 and 1.0 and 0.1 and 0.0 and 1000.0

  • Operating Voltage Rating And Type Per Function

    200.0 volts dc 6th radio interference 6th function

  • Source Impedance Rating Per Function

    50.0 ohms 6th radio interference

  • Style Designator

    filter connector

  • Special Features

    nuclear hardness critical item

  • Maximum Dielectric Withstanding Dc Voltage

    500.0 volts at sea level

  • Output Terminal Manufacturer Code

    73030

  • Source Impedance Rating Per Function

    50.0 ohms 1st radio interference

  • Vibration Resistance Range In Hertz

    +5.0/+1000.0

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...