NSN: 5915-01-338-9274
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Full Load Minimum Insertion Loss At Specified Frequency In Decibels
10.0 and 50.0 and 74.0 and 5.0 and 74.0 and 55.0
-
Maximum Temp Rise
25.0 deg celsius
-
Inclosure Type
encased
-
Body Height
40.0 millimeters nominal
-
Power Line Frequency Rating Per Function In Hertz
400.0 2nd radio interference
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Maximum Voltage Drop Per Function
2.5 volts ac 1st radio interference
-
End Item Identification
tactical air operations module an/tyq-23(v)1
-
Maximum Voltage Drop Per Function
2.5 volts ac 2nd radio interference
-
Operating Current Rating Per Function In Amps
3.0 2nd radio interference
-
Body Material
metal
-
Principal Circuitry Type Per Function
inductance-capacitance 2nd radio interference
-
Unpackaged Unit Weight
240.0 grams
-
Body Length
64.8 millimeters minimum and 67.0 millimeters maximum
-
Special Features
two filterer functions
-
Style Designator
rectangular terminal/terminals on opposite surfaces
-
Maximum Dielectric Withstanding Dc Voltage
500.0 volts at sea level
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Operating Voltage Rating And Type Per Function
250.0 volts ac 1st radio interference 1st function
-
Mounting Facility Type And Quantity
2 unthreaded hole
-
Overall Length
88.4 millimeters minimum and 90.6 millimeters maximum
-
Functional Terminal Type And Quantity
2 tab, solder lug input 1st function
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
75.0 millimeters nominal
-
Unthreaded Mounting Hole Diameter
5.1 millimeters nominal
-
Full Load Insertion Loss Frequencies In Megahertz
100.0 and 0.0 and 10.0 and 0.1 and 1.0 and 300.0
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Operating Voltage Rating And Type Per Function
250.0 volts ac 2nd radio interference 2nd function
-
Body Width
49.8 millimeters minimum and 52.0 millimeters maximum
-
Functional Terminal Type And Quantity
2 tab, solder lug output 2nd function
-
Operating Temp Range
-25.0/+85.0 deg celsius
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Operating Current Rating Per Function In Amps
3.0 1st radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 1st radio interference
-
Principal Circuitry Type Per Function
inductance-capacitance 1st radio interference