NSN: 5915-01-376-1993
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Inclosure Type
encased
-
Operating Current Rating Per Function In Amps
0.25 6th radio interference
-
Overall Length
1.930 inches minimum and 1.960 inches maximum
-
Source Impedance Rating Per Function
50.0 ohms 4th radio interference
-
Operating Temp Range
-55.0/+125.0 deg celsius
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Special Features
38 filtered functions
-
Features Provided
shock resistant
-
Functional Terminal Type And Quantity
38 friction w/grounding strap and pin input-output
-
Mounting Facility Type And Quantity
2 threaded hole
-
Body Material
metal
-
Source Impedance Rating Per Function
50.0 ohms 5th radio interference
-
Operating Current Rating Per Function In Amps
0.025 4th radio interference
-
Load Impedance Per Function
50.0 ohms 3rd radio interference
-
Operating Current Rating Per Function In Amps
0.025 5th radio interference
-
Source Impedance Rating Per Function
50.0 ohms 6th radio interference
-
Style Designator
filter connector
-
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
-
Maximum Dielectric Withstanding Dc Voltage
500.0 volts at sea level and 125.0 volts at altitude
-
Load Impedance Per Function
50.0 ohms 4th radio interference
-
Operating Voltage Rating And Type Per Function
150.0 volts dc 1st radio interference 1st function
-
Mounting Facility Screw Thread Series Designator
unc
-
Nominal Thread Size
0.112 inches
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.625 inches nominal
-
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
-
Load Impedance Per Function
50.0 ohms 5th radio interference
-
Operating Voltage Rating And Type Per Function
150.0 volts dc 2nd radio interference 2nd function
-
Operating Voltage Rating And Type Per Function
150.0 volts dc 3rd radio interference 3rd function
-
Operating Voltage Rating And Type Per Function
150.0 volts dc 4th radio interference 4th function
-
Load Impedance Per Function
50.0 ohms 6th radio interference
-
Operating Voltage Rating And Type Per Function
150.0 volts dc 5th radio interference 5th function
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Overall Height
1.030 inches maximum
-
Full Load Minimum Insertion Loss At Specified Frequency In Decibels
35.0 and 50.0 and 50.0 and 50.0
-
Operating Current Rating Per Function In Amps
0.25 1st radio interference
-
Operating Voltage Rating And Type Per Function
150.0 volts dc 6th radio interference 6th function
-
Operating Current Rating Per Function In Amps
0.25 2nd radio interference
-
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference
-
Operating Current Rating Per Function In Amps
0.25 3rd radio interference
-
Full Load Insertion Loss Frequencies In Megahertz
100.0 and 200.0 and 1000.0 and 10000.0
-
Overall Width
0.710 inches minimum and 0.740 inches maximum