NSN: 5915-01-399-4484
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Source Impedance Rating Per Function
50.0 cnb ohms per 1000 feet
-
Mounting Facility Type And Quantity
4 slot
-
Power Line Frequency Rating Per Function In Hertz
400.0 2nd radio interference
-
Load Impedance Per Function
50.0 ohms 4th radio interference
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 1st radio interference 1st function and 200.0 volts dc 1st radio interference 1st function
-
Mounting Slot Width
4.93 millimeters nominal
-
Load Impedance Per Function
50.0 ohms 5th radio interference
-
Inclosure Type
hermetically sealed
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 4th radio interference 4th function and 200.0 volts dc 4th radio interference 4th function
-
Overall Length
47.0 millimeters nominal
-
Overall Height
33.0 millimeters nominal
-
Operating Current Rating Per Function In Amps
7.5 1st radio interference
-
Functional Terminal Type And Quantity
8 friction w/grounding strap and pin input-output/ground
-
Load Impedance Per Function
50.0 ohms 6th radio interference
-
Load Impedance Per Function
50.0 ohms 1st radio interference
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 2nd radio interference 2nd function and 200.0 volts dc 2nd radio interference 2nd function
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 3rd radio interference 3rd function and 200.0 volts dc 3rd radio interference 3rd function
-
Source Impedance Rating Per Function
50.0 cnb gigohms
-
Operating Current Rating Per Function In Amps
7.5 2nd radio interference
-
Source Impedance Rating Per Function
50.0 cnb ohms impedance
-
Power Line Frequency Rating Per Function In Hertz
400.0 1st radio interference
-
Overall Width
33.0 millimeters nominal
-
Style Designator
filter connector
-
Load Impedance Per Function
50.0 ohms 3rd radio interference
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 6th radio interference 6th function and 200.0 volts dc 6th radio interference 6th function
-
Operating Voltage Rating And Type Per Function
115.0 volts ac 5th radio interference 5th function and 200.0 volts dc 5th radio interference 5th function
-
Body Material
metal
-
Power Line Frequency Rating Per Function In Hertz
400.0 6th radio interference
-
Operating Current Rating Per Function In Amps
7.5 6th radio interference
-
Load Impedance Per Function
50.0 ohms 2nd radio interference
-
Operating Current Rating Per Function In Amps
7.5 5th radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 5th radio interference
-
Source Impedance Rating Per Function
50.0 cnb ohms per mile
-
Operating Current Rating Per Function In Amps
7.5 4th radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 4th radio interference
-
Source Impedance Rating Per Function
50.0 cnb ohms per meter
-
Operating Current Rating Per Function In Amps
7.5 3rd radio interference
-
Power Line Frequency Rating Per Function In Hertz
400.0 3rd radio interference
-
Source Impedance Rating Per Function
50.0 cnb ohms per foot