NSN: 5915-01-551-7254
Filters and Networks
FILTER,RADIO FREQUENCY INTERFERENCE
FILTER,RADIO FREQUENCY INTERFERENCE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Test Data Document
81349-mil-prf-15733 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general
-
Operating Current Rating Per Function In Amps
0.5 blank
-
Load Impedance Per Function
50.0 ohms blank
-
Style Designator
round terminal/terminals on opposite surfaces
-
Body Outside Diameter
1.150 inches maximum
-
Maximum Voltage Drop Per Function
1.25 volts ac blank and 1.25 volts dc blank
-
Inclosure Type
hermetically sealed
-
End Item Identification
ps degaussing 20, 26, 40kw
-
Part Name Assigned By Controlling Agency
filters, radio frequency interference, style fl56
-
Mounting Facility Screw Thread Series Designator
unf
-
Nominal Thread Size
0.437 inches
-
Specification/Standard Data
81349-mil-prf-15733/74a government specification
-
Body Length
3.500 inches minimum and 3.620 inches maximum
-
~1
type data on certain environmental and performa
-
Operating Voltage Rating And Type Per Function
250.0 volts ac blank 1st function and 600.0 volts dc blank 1st function
-
Mounting Facility Type And Quantity
1 threaded bushing
-
Overall Length
4.580 inches maximum
-
Functional Terminal Type And Quantity
1 tab, solder lug input 1st function and 1 tab, solder lug output 1st function
-
Body Material
metal
-
Power Line Frequency Rating Per Function In Hertz
400.0 blank
-
Operating Temp Range
-55.0/+125.0 deg celsius
-
Source Impedance Rating Per Function
50.0 tnt any acceptable
-
Maximum Temp Rise
25.0 deg celsius