NSN: 5925-00-008-4201
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Trip Delay Time In Seconds Per Rated Continuous Current
75.000 minimum at 200 pct all locations and 325.000 maximum at 200 pct all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations
-
Body Style
multipole-single actuator type
-
Trip Release Ambient Temp Rating
50.0 deg celsius nominal all locations
-
Trip Release Method
thermal-magnetic all locations
-
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations
-
Center To Center Distance Between Terminals Parallel To Width
1.375 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.875 inches nominal
-
Body Length
6.562 inches nominal
-
Terminal Type And Quantity
4 screw
-
Actuator Function
trip-reset
-
Trip Release Characteristic
time delay all locations
-
Storage Type
general purpose warehouse
-
Actuator Position Designation
at pole one
-
Reset Method
manual
-
Pole Quantity
2
-
Circuit Protection Type
overcurrent all locations
-
Maximum Continuous Load Current Rating Per Pole
225.0 amperes ac all locations
-
Center To Center Distance Between Terminals Parallel To Length
6.530 inches nominal
-
Case Material
plastic
-
Body Width
2.800 inches nominal
-
Body Height
2.594 inches nominal
-
Unthreaded Mounting Hole Diameter
0.266 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.375 inches nominal
-
Boss Height
0.219 inches nominal
-
Inclosure Protection Type For Which Designed
general purpose
-
Main Contact Tripping Mechanism Type
trip free
-
Mounting Facility Type And Quantity
2 unthreaded hole
-
Frequency In Hertz
60.0 all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
10000.0 ac all locations
-
Manual Actuator Type And Quantity
1 toggle