NSN: 5925-00-012-2819

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Terminal Type And Quantity

    4 threaded stud

  • Thread Series Designator

    unc

  • Frequency In Hertz

    60.0

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 125.0 dc

  • Switch Terminal Type

    tab,solder lug

  • Inclosure Protection Type For Which Designed

    dustproof and fungus proof

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Actuator Position Designation

    between pole one and two

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Reset Method

    manual

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Trip Release Characteristic

    time delay

  • Trip Release Method

    magnetic-hydraulic

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac

  • Thread Quantity Per Inch

    32

  • Storage Type

    general purpose warehouse

  • Mounting Facility Type And Quantity

    4 threaded hole and 2 unthreaded hole

  • Arc Quenching Method

    magnetic blowout

  • Fragility Factor

    moderately rugged

  • Switch Contact Arrangement

    single pole,double throw

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Width

    0.974 inches minimum and 0.994 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    4.349 inches minimum and 4.369 inches maximum

  • Body Height

    2.677 inches minimum and 2.697 inches maximum

  • Body Width

    1.990 inches minimum and 2.010 inches maximum

  • Body Length

    5.240 inches minimum and 5.260 inches maximum

  • Switch Current Rating And Type In Amps

    15.0 ac and 15.0 dc

  • Trip Delay Time In Seconds Per Rated Continuous Current

    40.000 minimum at 200 pct and 120.000 maximum at 200 pct

  • Switch Location And Position Designation

    internal at pole one

  • Nominal Thread Size

    0.164 inches

  • Internal Trip Release Configuration

    series trip

  • Actuator Function

    trip-reset

  • Circuit Protection Type

    overcurrent

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac

  • Pole Quantity

    2

  • Boss Height

    0.208 inches minimum and 0.228 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.990 inches minimum and 1.010 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    3.052 inches minimum and 3.072 inches maximum

  • Unthreaded Mounting Hole Diameter

    0.190 inches nominal

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...