Technical Characteristics

  • Reference Number Differentiating Characteristics

    as differentiated by navord od36190

  • Body Style

    1b multipole-single actuator type

  • Body Width

    1.531 inches nominal

  • Case Material

    metal

  • Center To Center Distance Between Terminals Parallel To Length

    0.625 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    0.875 inches nominal

  • Mounting Surface To Terminal End Distance

    1.855 inches nominal

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Thread Quantity Per Inch

    32

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 dc all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Characteristic

    time delay all locations

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    at each pole

  • Nominal Thread Size

    0.375 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.100 minimum at 200 pct and 1.200 maximum at 200 pct and 0.030 minimum at 300 pct and 0.440 maximum at 300 pct and 0.010 minimum at 400 pct and 0.210 maximum at 400 pct all locations

  • Design Control Reference

    2315739p15

  • Manufacturers Code

    10001

  • Thread Series Designator

    unef

  • Terminal Type And Quantity

    6 wire hook

  • Bushing Length

    0.340 inches nominal

  • Body Length

    1.875 inches nominal

  • Pole Quantity

    3

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes dc all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc all locations

  • Trip Release Method

    magnetic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Ultimate Trip Time Per Pole In Seconds

    0.500 minimum and 5.000 maximum all locations

  • Actuator Function

    reset

  • Internal Trip Release Configuration

    series trip all locations

  • Inclosure Protection Type For Which Designed

    hermetically sealed

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...