NSN: 5925-00-013-1258

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Bushing Length

    0.340 inches nominal

  • Body Length

    1.531 inches nominal

  • Case Material

    metal

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Pole Quantity

    2

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac all locations

  • Trip Release Method

    magnetic all locations

  • Thread Series Designator

    unef

  • Reference Number Differentiating Characteristics

    as differentiated by special test features

  • Operating Voltage Type And Rating Per Pole In Volts

    230.0 ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Characteristic

    time delay all locations

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    at each pole

  • Nominal Thread Size

    0.375 inches

  • Design Control Reference

    2315741p59

  • Manufacturers Code

    10001

  • Body Style

    1b multipole-single actuator type

  • Body Width

    1.250 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Mounting Surface To Terminal End Distance

    1.855 inches nominal

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Thread Quantity Per Inch

    32

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Ultimate Trip Time Per Pole In Seconds

    2.400 minimum and 42.000 maximum all locations

  • Actuator Function

    reset

  • Internal Trip Release Configuration

    series trip all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.580 minimum at 200 pct and 6.000 maximum at 200 pct and 0.080 minimum at 300 pct and 1.600 maximum at 300 pct and 0.010 minimum at 400 pct and 0.630 maximum at 400 pct all locations

  • Inclosure Protection Type For Which Designed

    hermetically sealed

  • Frequency In Hertz

    60.0 all locations

  • Special Test Features

    navord od36190

  • Terminal Type And Quantity

    4 wire hook

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...