NSN: 5925-00-014-6182

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Bushing Length

    0.400 inches nominal

  • Body Width

    2.125 inches maximum

  • Case Material

    plastic

  • Body Style

    5b multipole-single actuator type

  • Center To Center Distance Between Terminals Parallel To Length

    0.750 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    0.688 inches nominal

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac and 5.0 amperes dc all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    125.0 ac and 28.0 dc all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 push-pull

  • Internal Trip Release Configuration

    series trip all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.800 minimum at 200 pct and 1.800 maximum at 200 pct all locations

  • Design Control Reference

    1950518-9

  • Manufacturers Code

    10001

  • Thread Series Designator

    uns

  • Terminal Type And Quantity

    6 threaded stud

  • Body Length

    1.265 inches maximum

  • Body Height

    2.200 inches maximum

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    thermal all locations

  • Trip Release Characteristic

    time delay all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 all locations

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole two

  • Nominal Thread Size

    0.469 inches

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal all locations

  • Frequency In Hertz

    400.0 all locations

  • Special Test Features

    navord od42046

  • Reference Number Differentiating Characteristics

    as differentiated by special test features

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...