NSN: 5925-00-018-1046
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Body Style
8c multipole-multiple actuator type
-
Case Material
plastic
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.050 inches minimum and 2.070 inches maximum
-
Iii Fragility Factor
moderately rugged
-
Boss Height
0.135 inches minimum and 0.165 inches maximum
-
Pole Quantity
3
-
Mounting Facility Type And Quantity
6 threaded hole
-
Iii Special Handling Feature
magnetic
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
1.0 amperes ac first location
-
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac third location
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Manual Actuator Type And Quantity
3 toggle
-
Actuator Function
trip-reset
-
External Actuator Linkage Arrangement
one, two, and three linked
-
Internal Trip Release Configuration
series trip all locations
-
Nominal Thread Size
0.138 inches
-
Trip Delay Time In Seconds Per Rated Continuous Current
6.000 minimum at 150 pct and 60.000 maximum at 150 pct and 2.000 minimum at 200 pct and 8.000 maximum at 200 pct and 0.400 minimum at 400 pct and 1.500 maximum at 400 pct all locations
-
Frequency In Hertz
420.0 all locations
-
Thread Series Designator
unc
-
Terminal Type And Quantity
6 threaded stud
-
Body Length
2.480 inches minimum and 2.500 inches maximum
-
Body Width
2.265 inches maximum
-
Center To Center Distance Between Terminals Parallel To Length
1.924 inches minimum and 1.952 inches maximum
-
Center To Center Distance Between Terminals Parallel To Width
0.735 inches minimum and 0.765 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.735 inches minimum and 0.765 inches maximum
-
Mounting Surface To Terminal End Distance
2.491 inches maximum
-
Iii Arc Quenching Method
magnetic blowout
-
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac second location
-
Circuit Protection Type
overcurrent all locations
-
Trip Release Method
magnetic all locations
-
Trip Release Characteristic
time delay all locations
-
Reset Method
manual
-
Main Contact Tripping Mechanism Type
trip free
-
Actuator Position Designation
at each pole
-
Inclosure Protection Type For Which Designed
hermetically sealed