NSN: 5925-00-022-4143
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.120 minimum at 200 pct and 0.160 maximum at 200 pct and 0.080 minimum at 400 pct and 0.140 maximum at 400 pct single location
-
Terminal Type And Quantity
2 threaded stud
-
Reference Number Differentiating Characteristics
as differentiated by special test features
-
Body Width
0.984 inches nominal
-
Case Material
plastic
-
Center To Center Distance Between Terminals Parallel To Length
3.062 inches nominal
-
Boss Height
0.156 inches nominal
-
Mounting Surface To Terminal End Distance
3.184 inches nominal
-
Mounting Facility Type And Quantity
2 threaded hole
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 dc single location
-
Trip Release Characteristic
time delay single location
-
Actuator Position Designation
at pole one
-
Internal Trip Release Configuration
series trip single location
-
Body Style
12a single pole type
-
Body Length
3.750 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.750 inches nominal
-
Pole Quantity
1
-
Thread Quantity Per Inch
32
-
Maximum Continuous Load Current Rating Per Pole
35.0 amperes dc single location
-
Operating Voltage Type And Rating Per Pole In Volts
32.0 dc single location
-
Circuit Protection Type
overcurrent single location
-
Trip Release Method
magnetic-hydraulic single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
-
Ultimate Trip Time Per Pole In Seconds
0.180 minimum and 2.000 maximum single location
-
Reset Method
manual
-
Main Contact Tripping Mechanism Type
trip free
-
Manual Actuator Type And Quantity
1 toggle
-
Actuator Function
reset
-
Nominal Thread Size
0.138 inches
-
Special Test Features
navord od42046
-
Design Control Reference
ps2-3904-6
-
Manufacturers Code
06887
-
Thread Series Designator
unc