NSN: 5925-00-022-4143

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.120 minimum at 200 pct and 0.160 maximum at 200 pct and 0.080 minimum at 400 pct and 0.140 maximum at 400 pct single location

  • Terminal Type And Quantity

    2 threaded stud

  • Reference Number Differentiating Characteristics

    as differentiated by special test features

  • Body Width

    0.984 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    3.062 inches nominal

  • Boss Height

    0.156 inches nominal

  • Mounting Surface To Terminal End Distance

    3.184 inches nominal

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 dc single location

  • Trip Release Characteristic

    time delay single location

  • Actuator Position Designation

    at pole one

  • Internal Trip Release Configuration

    series trip single location

  • Body Style

    12a single pole type

  • Body Length

    3.750 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Pole Quantity

    1

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    35.0 amperes dc single location

  • Operating Voltage Type And Rating Per Pole In Volts

    32.0 dc single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    magnetic-hydraulic single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Ultimate Trip Time Per Pole In Seconds

    0.180 minimum and 2.000 maximum single location

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    reset

  • Nominal Thread Size

    0.138 inches

  • Special Test Features

    navord od42046

  • Design Control Reference

    ps2-3904-6

  • Manufacturers Code

    06887

  • Thread Series Designator

    unc

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...