Technical Characteristics

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Width

    0.740 inches minimum and 0.760 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.052 inches minimum and 2.072 inches maximum

  • Boss Height

    0.130 inches minimum and 0.150 inches maximum

  • Mounting Surface To Terminal End Distance

    2.461 inches minimum and 2.481 inches maximum

  • Pole Quantity

    2

  • Arc Quenching Method

    magnetic blowout

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    1.0 amperes ac

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac

  • Trip Release Method

    magnetic

  • Manual Actuator Type And Quantity

    2 toggle

  • Internal Trip Release Configuration

    series trip

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    28.000 minimum at 200 pct and 90.000 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Switch Terminal Type

    turret

  • Switch Current Rating And Type In Amps

    2.5 ac and 1.0 dc

  • Switch Voltage Rating And Type In Volts

    240.0 ac and 50.0 dc

  • Thread Series Designator

    unc

  • Body Length

    2.490 inches minimum and 2.510 inches maximum

  • Body Width

    1.490 inches minimum and 1.510 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.928 inches minimum and 1.948 inches maximum

  • Switch Contact Arrangement

    single pole,double throw

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Fragility Factor

    moderately rugged

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac

  • Circuit Protection Type

    overcurrent

  • Trip Release Characteristic

    time delay

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • External Actuator Linkage Arrangement

    one and two linked

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Switch Location And Position Designation

    external at pole one

  • Frequency In Hertz

    60.0

  • Terminal Type And Quantity

    4 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...