NSN: 5925-00-064-5403
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Manufacturers Code
10001
-
Special Test Features
navord od42046
-
Frequency In Hertz
400.0 all locations
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal all locations
-
Actuator Position Designation
at each pole
-
Actuator Function
trip-reset
-
Manual Actuator Type And Quantity
1 push-pull
-
Reset Method
manual
-
Trip Release Method
thermal all locations
-
Maximum Continuous Load Current Rating Per Pole
2.5 amperes ac and 2.5 amperes dc all locations
-
Thread Quantity Per Inch
32
-
Mounting Facility Type And Quantity
1 threaded bushing
-
Pole Quantity
3
-
Body Height
2.200 inches maximum
-
Body Width
2.125 inches maximum
-
Body Length
1.265 inches maximum
-
Bushing Length
0.400 inches nominal
-
Body Style
5b multipole-single actuator type
-
Reference Number Differentiating Characteristics
as differentiated by special test features
-
Terminal Type And Quantity
6 threaded stud
-
Thread Series Designator
uns
-
Design Control Reference
1950518-4
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.400 minimum at 200 pct and 1.800 maximum at 200 pct all locations
-
Nominal Thread Size
0.469 inches
-
Internal Trip Release Configuration
series trip all locations
-
Main Contact Tripping Mechanism Type
trip free
-
Ultimate Trip Time Per Pole In Seconds
3600.000 nominal all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 all locations
-
Trip Release Characteristic
time delay all locations
-
Circuit Protection Type
overcurrent all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac all locations
-
Operating Voltage Type And Rating Per Pole In Volts
125.0 ac and 28.0 dc all locations
-
Center To Center Distance Between Terminals Parallel To Width
0.688 inches nominal
-
Center To Center Distance Between Terminals Parallel To Length
0.750 inches nominal
-
Case Material
plastic