NSN: 5925-00-064-5403

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Manufacturers Code

    10001

  • Special Test Features

    navord od42046

  • Frequency In Hertz

    400.0 all locations

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal all locations

  • Actuator Position Designation

    at each pole

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    1 push-pull

  • Reset Method

    manual

  • Trip Release Method

    thermal all locations

  • Maximum Continuous Load Current Rating Per Pole

    2.5 amperes ac and 2.5 amperes dc all locations

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Pole Quantity

    3

  • Body Height

    2.200 inches maximum

  • Body Width

    2.125 inches maximum

  • Body Length

    1.265 inches maximum

  • Bushing Length

    0.400 inches nominal

  • Body Style

    5b multipole-single actuator type

  • Reference Number Differentiating Characteristics

    as differentiated by special test features

  • Terminal Type And Quantity

    6 threaded stud

  • Thread Series Designator

    uns

  • Design Control Reference

    1950518-4

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.400 minimum at 200 pct and 1.800 maximum at 200 pct all locations

  • Nominal Thread Size

    0.469 inches

  • Internal Trip Release Configuration

    series trip all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Time Per Pole In Seconds

    3600.000 nominal all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 all locations

  • Trip Release Characteristic

    time delay all locations

  • Circuit Protection Type

    overcurrent all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    125.0 ac and 28.0 dc all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.688 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    0.750 inches nominal

  • Case Material

    plastic

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...