NSN: 5925-00-079-5679

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Case Material

    plastic

  • Iii Arc Quenching Method

    magnetic blowout

  • Iii Storage Type

    general purpose warehouse

  • Iii Special Handling Feature

    magnetic

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    magnetic-hydraulic single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Nominal Thread Size

    0.138 inches

  • Inclosure Protection Type For Which Designed

    dustproof and fungus proof

  • Terminal Type And Quantity

    2 threaded stud

  • Body Style

    4a single pole type

  • Body Length

    2.500 inches nominal

  • Body Width

    0.750 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    1.938 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.062 inches nominal

  • Iii Fragility Factor

    moderately rugged

  • Mounting Surface To Terminal End Distance

    2.611 inches nominal

  • Pole Quantity

    1

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    35.0 amperes ac single location

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac single location

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Internal Trip Release Configuration

    series trip single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    4.000 minimum at 200 pct and 10.000 maximum at 200 pct single location

  • Frequency In Hertz

    60.0 single location

  • Thread Series Designator

    unc

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...