NSN: 5925-00-080-1657

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Terminal Type And Quantity

    4 threaded stud

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.700 minimum at 300 pct and

  • External Actuator Linkage Arrangement

    one and two linked

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Characteristic

    time delay all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Iii Arc Quenching Method

    magnetic blowout

  • Mounting Surface To Terminal End Distance

    2.810 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.740 inches minimum and

  • Center To Center Distance Between Terminals Parallel To Width

    0.740 inches minimum and

  • Center To Center Distance Between Terminals Parallel To Length

    1.928 inches minimum and

  • Case Material

    plastic

  • Body Width

    1.490 inches minimum and

  • Body Length

    2.490 inches minimum and

  • Thread Series Designator

    unc

  • Frequency In Hertz

    400.0 all locations

  • Inclosure Protection Type For Which Designed

    fungus proof

  • Inclosure Protection Type For Which Designed

    dustproof and

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 maximum at 300 pct all locations

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip all locations

  • Actuator Position Designation

    at each pole

  • Actuator Function

    trip-reset

  • Manual Actuator Type And Quantity

    2 toggle

  • Reset Method

    manual

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Trip Release Method

    magnetic all locations

  • Circuit Protection Type

    overcurrent all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Maximum Continuous Load Current Rating Per Pole

    1.0 amperes ac all locations

  • Thread Quantity Per Inch

    32

  • Iii Storage Type

    general purpose warehouse

  • Pole Quantity

    2

  • Boss Height

    0.175 inches maximum

  • Boss Height

    0.155 inches minimum and

  • Iii Fragility Factor

    moderately rugged

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.760 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.072 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.052 inches minimum and

  • Center To Center Distance Between Terminals Parallel To Width

    0.760 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.948 inches maximum

  • Body Width

    1.510 inches maximum

  • Body Length

    2.510 inches maximum

  • Body Style

    8c multipole-multiple actuator type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...