NSN: 5925-00-080-2162

Technical Characteristics

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    10000.0 ac all locations

  • Frequency In Hertz

    60.0 all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.740 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Inclosure Protection Type For Which Designed

    corrosion resistant

  • Specification/Standard Data

    81348-w-c-375/3 government specification

  • Case Material

    plastic

  • Test Data Document

    81348-w-c-375 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Manual Actuator Type And Quantity

    1 toggle

  • Body Length

    3.000 inches nominal

  • Boss Height

    0.250 inches nominal

  • Body Style

    multipole-single actuator type

  • Actuator Position Designation

    at pole two

  • Terminal Type And Quantity

    3 clip and 3 compression

  • Trip Release Method

    thermal-magnetic all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.000 maximum at 200 pct all locations

  • Body Height

    2.360 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    135.0 all locations

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac all locations

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Storage Type

    general purpose warehouse

  • Reset Method

    manual

  • Body Width

    1.480 inches nominal

  • Circuit Protection Type

    overcurrent all locations

  • Mounting Facility Type And Quantity

    6 terminal

  • Pole Quantity

    3

  • Special Handling Feature

    magnetic

  • Fragility Factor

    moderately rugged

  • ~1

    data on certain environmental and performance re

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.