NSN: 5925-00-080-5835

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Inclosure Protection Type For Which Designed

    dustproof

  • Body Style

    rectangular dimensional envelope

  • Reset Method

    manual

  • Overall Length

    9.500 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.190 inches nominal

  • Adjustable Trip Setting Current Range Per Pole In Amps

    +1300.0/+2500.0 ac all locations and +1300.0/+2500.0 dc all locations

  • Overall Height

    4.125 inches nominal

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Delay Time In Seconds Per Rated Continuous Current

    70.000 minimum at 200 pct all locations and 160.000 maximum at 200 pct all locations

  • Terminal Type And Quantity

    6 compression

  • Frequency In Hertz

    60.0 all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Manual Actuator Type And Quantity

    1 rotary

  • Overall Width

    4.375 inches nominal

  • Trip Release Method

    thermal-magnetic all locations

  • Packaged Unit Weight

    7.500 pounds

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac all locations and 250.0 dc all locations

  • Features Provided

    adjustable trip release and handle lock

  • Trip Release Characteristic

    instantaneous all locations and time delay all locations

  • Actuator Function

    trip-reset

  • Trip Release Ambient Temp Rating

    40.0 deg celsius nominal all locations

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Maximum Continuous Load Current Rating Per Pole

    225.0 amperes ac all locations and 225.0 amperes dc all locations

  • Case Material

    plastic

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    15000.0 ac all locations and 10000.0 dc all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.