NSN: 5925-00-080-7507

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Delay Time In Seconds Per Rated Continuous Current

    1.000 minimum at 200 pct all locations and 8.000 maximum at 200 pct all locations

  • Body Length

    5.125 inches nominal

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic-hydraulic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.688 inches nominal

  • Body Style

    multipole-single actuator type

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes dc first location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.984 inches nominal

  • Manual Actuator Type And Quantity

    1 toggle

  • Unthreaded Mounting Hole Diameter

    0.164 inches nominal

  • Actuator Position Designation

    between pole one and two

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Operating Voltage Type And Rating Per Pole In Volts

    125.0 dc all locations

  • Boss Height

    0.219 inches nominal

  • Body Width

    2.000 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    4.359 inches nominal

  • Terminal Type And Quantity

    4 threaded stud

  • Body Height

    2.688 inches nominal

  • Case Material

    plastic

  • Inclosure Protection Type For Which Designed

    fungus proof and shock resistant and vibration resistant and moisture proof

  • Fragility Factor

    moderately rugged

  • Mounting Facility Type And Quantity

    2 threaded hole and 4 unthreaded hole

  • Special Handling Feature

    magnetic

  • Circuit Protection Type

    overcurrent all locations

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes dc second location

  • Pole Quantity

    2

  • Nominal Thread Size

    0.190 inches

  • Reset Method

    manual

  • Thread Series Designator

    unf

  • Storage Type

    general purpose warehouse

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 dc all locations

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.984 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...