NSN: 5925-00-083-1663

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Bushing Length

    0.235 inches minimum and 0.265 inches maximum

  • Body Length

    2.189 inches maximum

  • Body Width

    0.750 inches maximum

  • Case Material

    plastic

  • Nonturn Device Length

    0.045 inches nominal

  • Pole Quantity

    1

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac single location and 20.0 volt-ampere and 500.0 volt-ampere and 5.0 amperes dc

  • Circuit Protection Type

    overcurrent single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Nominal Thread Size

    0.469 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    15.000 minimum at 200 pct single location and 55.000 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    vibration resistant and shock resistant

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Frequency In Hertz

    400.0 single location

  • Body Style

    1a single pole type

  • Center To Center Distance Between Terminals Parallel To Length

    0.704 inches nominal

  • Nonturn Device Location

    at 12 oclock

  • Nonturn Device Radius

    0.370 inches minimum and 0.380 inches maximum

  • Nonturn Device Width

    0.088 inches minimum and feet

  • Mounting Surface To Terminal End Distance

    1.860 inches maximum

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Storage Type

    general purpose warehouse

  • Operating Voltage Type And Rating Per Pole In Volts

    30.0 dc single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    6000.0 dc single location

  • Trip Release Method

    thermal single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Reset Method

    manual

  • Manual Actuator Type And Quantity

    1 push-pull

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Internal Trip Release Configuration

    series trip single location

  • Unpackaged Unit Weight

    43.0 grams

  • Thread Series Designator

    uns

  • Terminal Type And Quantity

    2 tab w/screw

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...