NSN: 5925-00-087-9944

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Release Method

    thermal all locations

  • Case Material

    plastic

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    28.000 minimum at 200 pct all locations and 65.000 maximum at 200 pct all locations

  • Body Length

    9.500 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    120.0 all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.375 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.219 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    15000.0 ac all locations

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Main Contact Tripping Mechanism Type

    trip free

  • Terminal Type And Quantity

    6 compression

  • Frequency In Hertz

    60.0 all locations

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal all locations

  • Boss Height

    0.250 inches nominal

  • Manual Actuator Type And Quantity

    1 rotary

  • Body Style

    multipole-single actuator type

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    7.250 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    8.000 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    1.375 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac all locations

  • Internal Trip Release Configuration

    series trip all locations

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Reset Method

    manual

  • Body Width

    4.125 inches nominal

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

  • Fragility Factor

    moderately rugged

  • Body Height

    3.812 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...