NSN: 5925-00-088-9503

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Release Method

    magnetic-hydraulic single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    8.000 minimum at 125 pct single location and 4.000 maximum at 200 pct single location

  • Body Length

    2.490 inches minimum and 2.510 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    32.0 dc single location

  • Boss Height

    0.130 inches minimum and 0.150 inches maximum

  • Case Material

    plastic

  • Terminal Type And Quantity

    2 threaded stud

  • Body Style

    single pole type

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.052 inches minimum and 2.072 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3000.0 dc single location

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    2 threaded stud

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Trip Release Characteristic

    time delay single location

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Pole Quantity

    1

  • Circuit Protection Type

    overcurrent single location

  • Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Thread Quantity Per Inch

    32

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Center To Center Distance Between Terminals Parallel To Length

    1.928 inches minimum and 1.948 inches maximum

  • Mounting Surface To Terminal End Distance

    2.461 inches minimum and 2.481 inches maximum

  • Reset Method

    manual

  • Thread Series Designator

    unc

  • Maximum Continuous Load Current Rating Per Pole

    1.0 amperes dc single location

  • Fragility Factor

    moderately rugged

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...