NSN: 5925-00-092-0411
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Thread Quantity Per Inch
32
-
Body Length
1.985 inches minimum and 2.015 inches maximum
-
Circuit Protection Type
overcurrent single location
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.180 minimum at 200 pct single location and 1.800 maximum at 200 pct single location
-
Pole Quantity
1
-
Nonturn Device Diameter
0.151 inches minimum and 0.161 inches maximum
-
Reset Method
manual
-
Manual Actuator Type And Quantity
1 toggle
-
Nominal Thread Size
0.500 inches
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Actuator Position Designation
at pole one
-
Storage Type
general purpose warehouse
-
Actuator Function
trip-reset
-
Terminal Type And Quantity
2 screw
-
Fragility Factor
moderately rugged
-
Special Handling Feature
magnetic
-
Center To Center Distance Between Terminals Parallel To Length
1.515 inches minimum and 1.545 inches maximum
-
Internal Trip Release Configuration
series trip single location
-
Trip Release Characteristic
time delay single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
magnetic blowout
-
Frequency In Hertz
50.0 single location or 60.0 single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 ac single location
-
Mounting Surface To Terminal End Distance
2.232 inches maximum
-
Body Style
single pole type
-
Inclosure Protection Type For Which Designed
moisture resistant and salt spray proof and shock resistant and vibration resistant
-
Nonturn Device Radius
0.641 inches minimum and 0.671 inches maximum
-
Maximum Continuous Load Current Rating Per Pole
35.0 amperes ac single location
-
Trip Release Method
magnetic-hydraulic single location
-
Body Width
0.735 inches minimum and 0.765 inches maximum
-
Bushing Length
0.480 inches minimum and 0.510 inches maximum
-
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac single location
-
Unpackaged Unit Weight
3.000 ounces
-
Thread Series Designator
un
-
Nonturn Device Length
0.115 inches minimum and 0.145 inches maximum
-
Case Material
plastic