NSN: 5925-00-092-0411

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Thread Quantity Per Inch

    32

  • Body Length

    1.985 inches minimum and 2.015 inches maximum

  • Circuit Protection Type

    overcurrent single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.180 minimum at 200 pct single location and 1.800 maximum at 200 pct single location

  • Pole Quantity

    1

  • Nonturn Device Diameter

    0.151 inches minimum and 0.161 inches maximum

  • Reset Method

    manual

  • Manual Actuator Type And Quantity

    1 toggle

  • Nominal Thread Size

    0.500 inches

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Terminal Type And Quantity

    2 screw

  • Fragility Factor

    moderately rugged

  • Special Handling Feature

    magnetic

  • Center To Center Distance Between Terminals Parallel To Length

    1.515 inches minimum and 1.545 inches maximum

  • Internal Trip Release Configuration

    series trip single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Frequency In Hertz

    50.0 single location or 60.0 single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 ac single location

  • Mounting Surface To Terminal End Distance

    2.232 inches maximum

  • Body Style

    single pole type

  • Inclosure Protection Type For Which Designed

    moisture resistant and salt spray proof and shock resistant and vibration resistant

  • Nonturn Device Radius

    0.641 inches minimum and 0.671 inches maximum

  • Maximum Continuous Load Current Rating Per Pole

    35.0 amperes ac single location

  • Trip Release Method

    magnetic-hydraulic single location

  • Body Width

    0.735 inches minimum and 0.765 inches maximum

  • Bushing Length

    0.480 inches minimum and 0.510 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location

  • Unpackaged Unit Weight

    3.000 ounces

  • Thread Series Designator

    un

  • Nonturn Device Length

    0.115 inches minimum and 0.145 inches maximum

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...