NSN: 5925-00-097-7471

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Unpackaged Unit Weight

    1.770 pounds

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    6 threaded stud

  • Body Width

    3.062 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Width

    1.030 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.031 inches nominal

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    3

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac

  • Circuit Protection Type

    overcurrent

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    3 toggle

  • Nominal Thread Size

    0.138 inches

  • Frequency In Hertz

    400.0

  • Body Length

    3.060 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    1.125 inches nominal

  • Boss Height

    0.170 inches nominal

  • Mounting Surface To Terminal End Distance

    3.239 inches nominal

  • Arc Quenching Method

    magnetic blowout

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1500.0 ac

  • Trip Release Method

    magnetic

  • Trip Release Characteristic

    time delay

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • External Actuator Linkage Arrangement

    one,two,and three linked

  • Internal Trip Release Configuration

    series trip

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.500 minimum at 200 pct and 8.500 maximum at 200 pct

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...