NSN: 5925-00-098-9563

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Center To Center Distance Between Terminals Parallel To Length

    9.531 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    2.750 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.312 inches nominal

  • Fragility Factor

    moderately rugged

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    4.000 ac all locations

  • Trip Release Characteristic

    instantaneous all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    at pole two

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Body Length

    10.750 inches nominal

  • Case Material

    plastic

  • Frequency In Hertz

    60.0

  • Terminal Type And Quantity

    6 wire lead

  • Body Style

    11b multipole-single actuator type

  • Body Width

    8.250 inches nominal

  • Body Height

    4.062 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    9.750 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    2.750 inches nominal

  • Boss Height

    0.250 inches nominal

  • Pole Quantity

    3

  • Arc Quenching Method

    deion

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Storage Type

    general purpose warehouse

  • Maximum Continuous Load Current Rating Per Pole

    400.0 amperes ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    magnetic all locations

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Special Features

    high magnetic trip with fixed trip setting

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...