NSN: 5925-00-102-5990

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    12a single pole type

  • Case Material

    plastic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.062 inches nominal

  • Switch Contact Arrangement

    single pole, single throw, normally closed

  • Iii Fragility Factor

    moderately rugged

  • Pole Quantity

    1

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Iii Special Handling Feature

    magnetic

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes dc single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 dc single location

  • Trip Release Method

    magnetic single location

  • Trip Release Characteristic

    time delay single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.138 inches

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 30.0 dc

  • Thread Series Designator

    unc

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Position Designation

    at pole one

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Switch Location And Position Designation

    external at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.300 minimum at 200 pct and 6.500 maximum at 200 pct single location

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant and explosion resistant

  • Switch Terminal Type

    tab, solder lug

  • Switch Current Rating And Type In Amps

    10.0 ac and 2.5 dc

  • Terminal Type And Quantity

    2 threaded stud

  • Circuit Protection Type

    overcurrent single location

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc single location

  • Iii Storage Type

    general purpose warehouse

  • Iii Arc Quenching Method

    magnetic blowout

  • Mounting Surface To Terminal End Distance

    2.611 inches nominal

  • Boss Height

    0.140 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    1.938 inches nominal

  • Body Width

    0.750 inches nominal

  • Body Length

    2.500 inches nominal

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...