Technical Characteristics

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Thread Quantity Per Inch

    32

  • Manual Actuator Type And Quantity

    1 push-pull

  • Actuator Position Designation

    at pole two

  • Unpackaged Unit Weight

    3.250 ounces

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Body Style

    multipole-single actuator type

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal all locations

  • Nominal Thread Size

    0.138 inches

  • Center To Center Distance Between Terminals Parallel To Width

    0.720 inches minimum and 0.780 inches maximum

  • Main Contact Tripping Mechanism Type

    trip free

  • Body Height

    2.340 inches minimum and 2.400 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.161 inches minimum and 1.220 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    15.000 minimum at 200 pct all locations and 65.000 maximum at 200 pct all locations

  • Inclosure Protection Type For Which Designed

    general purpose

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 all locations

  • Maximum Continuous Load Current Rating Per Pole

    25.0 amperes ac all locations

  • Bushing Length

    0.235 inches minimum and 0.250 inches maximum

  • Frequency In Hertz

    400.0 all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac all locations

  • Body Length

    2.250 inches maximum

  • Terminal Type And Quantity

    6 tab w/screw

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    6000.0 ac all locations

  • Case Material

    plastic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.470 inches minimum and 1.530 inches maximum

  • Trip Release Method

    thermal all locations

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.720 inches minimum and 0.780 inches maximum

  • Body Width

    2.189 inches maximum

  • Thread Series Designator

    unc

  • Test Data Document

    98897-stsvc004 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)

  • Reset Method

    manual

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...