NSN: 5925-00-103-3882

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Release Ambient Temp Rating

    50.0 deg celsius maximum all locations

  • Center To Center Distance Between Terminals Parallel To Length

    8.875 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    8.437 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Fragility Factor

    moderately rugged

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.719 inches nominal

  • Reset Method

    manual

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Body Length

    10.125 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    175.0 amperes ac all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Body Height

    4.062 inches nominal

  • Unthreaded Mounting Hole Diameter

    0.281 inches nominal

  • Actuator Position Designation

    at pole two

  • Body Width

    5.500 inches nominal

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Trip Delay Time In Seconds Per Rated Continuous Current

    170.000 minimum at 200 pct all locations and 460.000 maximum at 200 pct all locations

  • Body Style

    multipole-single actuator type

  • Boss Height

    0.250 inches nominal

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Terminal Type And Quantity

    6 compression

  • Main Contact Tripping Mechanism Type

    trip free

  • Mounting Facility Type And Quantity

    4 unthreaded hole

  • Center To Center Distance Between Terminals Parallel To Width

    1.719 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    25000.0 ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    600.0 ac all locations

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...