NSN: 5925-00-117-8093

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Maximum Continuous Load Current Rating Per Pole

    200.0 amperes ac single location and 200.0 amperes dc single location

  • Bushing Length

    0.250 inches nominal

  • Thread Series Designator

    unc

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.812 inches nominal

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Thread Quantity Per Inch

    32

  • Inclosure Protection Type For Which Designed

    vibration resistant and shock resistant

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Arc Quenching Method

    air

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Trip Delay Time In Seconds Per Rated Continuous Current

    15.000 minimum at 200 pct single location and 70.000 maximum at 200 pct single location

  • Manual Actuator Type And Quantity

    1 push-pull

  • Center To Center Distance Between Terminals Parallel To Length

    1.438 inches nominal

  • Pole Quantity

    1

  • Case Material

    metal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2500.0 ac single location and 3000.0 dc single location

  • Body Length

    2.189 inches maximum

  • Internal Trip Release Configuration

    series trip single location

  • Mounting Surface To Terminal End Distance

    2.250 inches maximum

  • Nominal Thread Size

    0.138 inches

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac single location and 28.0 dc single location

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Frequency In Hertz

    400.0 single location

  • Unpackaged Unit Weight

    130.0 grams

  • Body Style

    single pole type

  • Terminal Type And Quantity

    2 tab w/screw

  • Body Width

    1.000 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...