NSN: 5925-00-137-4504

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac all locations

  • ~1

    data on certain environmental and performanc

  • Test Data Document

    81349-mil-c-39019 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Switch Terminal Type

    tab, solder lug

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Bushing Length

    0.280 inches minimum and 0.380 inches maximum

  • Reset Method

    manual

  • Switch Location And Position Designation

    internal at pole three

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Actuator Position Designation

    at pole two

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Switch Contact Arrangement

    single pole, double throw

  • Body Style

    multipole-single actuator type

  • Case Material

    metal

  • Manual Actuator Type And Quantity

    1 toggle

  • Main Contact Tripping Mechanism Type

    trip free

  • Switch Current Rating And Type In Amps

    0.5 ac and 0.5 dc

  • Body Width

    1.562 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    9.000 maximum at 200 pct all locations and 0.500 minimum at 200 pct all locations and 1.750 maximum at 400 pct all locations

  • Frequency In Hertz

    400.0 all locations

  • Thread Series Designator

    unef

  • Switch Voltage Rating And Type In Volts

    120.0 ac and 50.0 dc

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Maximum Continuous Load Current Rating Per Pole

    7.0 amperes ac all locations

  • Body Length

    1.937 inches maximum

  • Ultimate Trip Time Per Pole In Seconds

    3.000 minimum all locations and 60.000 maximum all locations

  • Terminal Type And Quantity

    6 wire hook

  • Trip Release Characteristic

    time delay all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Mounting Facility Type And Quantity

    thd bushing w/panel seal

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Trip Release Method

    magnetic all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...