NSN: 5925-00-140-2359
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Internal Trip Release Configuration
relay trip fourth location
-
Mounting Surface To Terminal End Distance
3.234 inches nominal
-
Circuit Protection Type
overcurrent all locations
-
Terminal Type And Quantity
10 threaded stud
-
Thread Series Designator
unc
-
Actuator Position Designation
at each pole
-
Reset Method
manual
-
Actuator Function
trip-reset
-
Center To Center Distance Between Terminals Parallel To Width
1.031 inches maximum
-
Thread Quantity Per Inch
32
-
Mounting Facility Type And Quantity
8 threaded hole
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
500.0 ac all locations
-
Trip Release Method
magnetic all locations
-
Body Style
multipole-multiple actuator type
-
Internal Trip Release Configuration
series trip first location
-
Trip Delay Time In Seconds Per Rated Continuous Current
6.000 minimum at 200 pct third location and 20.000 maximum at 200 pct third location
-
Body Width
4.199 inches maximum
-
Trip Release Characteristic
time delay first location
-
External Actuator Linkage Arrangement
one, two, three, and four linked
-
Inclosure Protection Type For Which Designed
fungus resistant and moisture resistant
-
Internal Trip Release Configuration
series trip second location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations
-
Nominal Thread Size
0.138 inches
-
Trip Release Characteristic
time delay second location
-
Internal Trip Release Configuration
series trip third location
-
Trip Delay Time In Seconds Per Rated Continuous Current
6.000 minimum at 200 pct first location and 20.000 maximum at 200 pct first location
-
Center To Center Distance Between Terminals Parallel To Length
3.547 inches nominal
-
Main Contact Tripping Mechanism Type
trip free
-
Trip Release Characteristic
time delay third location
-
Maximum Continuous Load Current Rating Per Pole
30.0 amperes ac all locations
-
Trip Release Characteristic
instantaneous fourth location
-
Boss Height
0.219 inches nominal
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.031 inches maximum
-
Trip Delay Time In Seconds Per Rated Continuous Current
6.000 minimum at 200 pct second location and 20.000 maximum at 200 pct second location
-
Frequency In Hertz
400.0 all locations
-
Body Length
4.750 inches nominal
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.750 inches nominal
-
Manual Actuator Type And Quantity
4 toggle
-
Case Material
plastic
-
Pole Quantity
4