NSN: 5925-00-140-2359

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Internal Trip Release Configuration

    relay trip fourth location

  • Mounting Surface To Terminal End Distance

    3.234 inches nominal

  • Circuit Protection Type

    overcurrent all locations

  • Terminal Type And Quantity

    10 threaded stud

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Center To Center Distance Between Terminals Parallel To Width

    1.031 inches maximum

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    8 threaded hole

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 ac all locations

  • Trip Release Method

    magnetic all locations

  • Body Style

    multipole-multiple actuator type

  • Internal Trip Release Configuration

    series trip first location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    6.000 minimum at 200 pct third location and 20.000 maximum at 200 pct third location

  • Body Width

    4.199 inches maximum

  • Trip Release Characteristic

    time delay first location

  • External Actuator Linkage Arrangement

    one, two, three, and four linked

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Internal Trip Release Configuration

    series trip second location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Nominal Thread Size

    0.138 inches

  • Trip Release Characteristic

    time delay second location

  • Internal Trip Release Configuration

    series trip third location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    6.000 minimum at 200 pct first location and 20.000 maximum at 200 pct first location

  • Center To Center Distance Between Terminals Parallel To Length

    3.547 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Characteristic

    time delay third location

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac all locations

  • Trip Release Characteristic

    instantaneous fourth location

  • Boss Height

    0.219 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.031 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    6.000 minimum at 200 pct second location and 20.000 maximum at 200 pct second location

  • Frequency In Hertz

    400.0 all locations

  • Body Length

    4.750 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Manual Actuator Type And Quantity

    4 toggle

  • Case Material

    plastic

  • Pole Quantity

    4

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...