NSN: 5925-00-144-0462

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Inclosure Protection Type For Which Designed

    dustproof

  • Ultimate Trip Time Per Pole In Seconds

    3600.000 nominal single location

  • Thread Series Designator

    unc

  • Actuator Function

    trip w/separate reset

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.812 inches nominal

  • Body Length

    2.203 inches nominal

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.200 minimum at 200 pct single location and 2.000 maximum at 200 pct single location

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Center To Center Distance Between Terminals Parallel To Length

    1.438 inches nominal

  • Pole Quantity

    1

  • Maximum Continuous Load Current Rating Per Pole

    60.0 amperes dc single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Nominal Thread Size

    0.164 inches

  • Body Style

    single pole type

  • Mounting Surface To Terminal End Distance

    1.406 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1200.0 dc single location

  • Terminal Type And Quantity

    2 tab w/screw

  • Body Width

    0.766 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    30.0 dc single location

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...