NSN: 5925-00-146-0057
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Bushing Length
0.380 inches maximum
-
Body Length
1.500 inches maximum
-
Pole Quantity
3
-
Circuit Protection Type
overcurrent
-
Reset Method
manual
-
Terminal Type And Quantity
6 wire hook
-
Body Width
1.875 inches maximum
-
Case Material
metal
-
Center To Center Distance Between Terminals Parallel To Length
0.875 inches nominal
-
Center To Center Distance Between Terminals Parallel To Width
0.625 inches nominal
-
Mounting Surface To Terminal End Distance
1.780 inches maximum
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Trip Release Method
magnetic
-
Main Contact Tripping Mechanism Type
trip free
-
Nominal Thread Size
0.375 inches
-
Thread Series Designator
unef