NSN: 5925-00-151-9681

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Inclosure Protection Type For Which Designed

    dustproof

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1500.0 ac single location

  • Reset Method

    manual

  • Center To Center Distance Between Terminals Parallel To Length

    2.740 inches minimum and 2.760 inches maximum

  • Boss Height

    0.115 inches minimum and 0.135 inches maximum

  • Actuator Position Designation

    at pole one

  • Body Length

    3.208 inches minimum and 3.228 inches maximum

  • Body Style

    single pole type

  • Body Width

    1.476 inches minimum and 1.496 inches maximum

  • Trip Release Method

    magnetic-hydraulic single location

  • Frequency In Hertz

    60.0 single location

  • Trip Release Characteristic

    instantaneous single location

  • Case Material

    plastic

  • Arc Quenching Method

    magnetic blowout

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Mounting Facility Type And Quantity

    2 unthreaded hole

  • Unthreaded Mounting Hole Diameter

    0.164 inches nominal

  • Internal Trip Release Configuration

    series trip single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Maximum Continuous Load Current Rating Per Pole

    12.5 amperes ac single location

  • Pole Quantity

    1

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac single location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.302 inches minimum and 1.322 inches maximum

  • Circuit Protection Type

    overcurrent single location

  • Body Height

    2.646 inches minimum and 2.666 inches maximum

  • Terminal Type And Quantity

    2 screw

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

Related Manufacturers

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...