NSN: 5925-00-153-4513
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Internal Trip Release Configuration
series trip single location
-
Manual Actuator Type And Quantity
1 toggle
-
Trip Delay Time In Seconds Per Rated Continuous Current
40.000 nominal at 200 pct single location and 7.000 nominal at 300 pct single location
-
Pole Quantity
1
-
Trip Release Ambient Temp Rating
25.0 deg celsius minimum single location
-
Circuit Protection Type
overcurrent single location
-
Thread Quantity Per Inch
32
-
Mounting Facility Type And Quantity
2 threaded hole
-
Actuator Function
trip-reset
-
Actuator Position Designation
at pole one
-
Reset Method
manual
-
Thread Series Designator
unc
-
Maximum Continuous Load Current Rating Per Pole
80.0 amperes dc single location
-
Inclosure Protection Type For Which Designed
dustproof
-
Terminal Type And Quantity
2 threaded stud
-
Case Material
plastic
-
Operating Voltage Type And Rating Per Pole In Volts
30.0 dc single location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 single location
-
Trip Release Method
magnetic-hydraulic single location
-
Main Contact Tripping Mechanism Type
trip free
-
Trip Release Characteristic
time delay single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1500.0 dc single location