NSN: 5925-00-167-5475

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    240.0 ac all locations and 240.0 dc all locations

  • Switch Contact Arrangement

    single pole, double throw

  • Body Style

    multipole-single actuator type

  • Maximum Continuous Load Current Rating Per Pole

    240.0 milliamperes ac all locations and 240.0 milliamperes dc all locations

  • Case Material

    metal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.001 minimum at 400 pct all locations and 0.950 maximum at 200 pct all locations and 0.055 minimum at 200 pct all locations and 0.240 maximum at 400 pct all locations

  • Manual Actuator Type And Quantity

    1 toggle

  • Switch Location And Position Designation

    external at pole three

  • Main Contact Tripping Mechanism Type

    trip free

  • Switch Current Rating And Type In Amps

    0.5 ac and 0.5 dc

  • Inclosure Protection Type For Which Designed

    weatherproof

  • Body Width

    1.562 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches maximum

  • Ultimate Trip Time Per Pole In Seconds

    0.200 minimum all locations and 7.000 maximum all locations

  • Frequency In Hertz

    400.0 all locations

  • Switch Terminal Type

    pin

  • Thread Series Designator

    unef

  • Switch Voltage Rating And Type In Volts

    120.0 ac and 50.0 dc

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations and 240.0 dc all locations

  • Terminal Type And Quantity

    6 wire hook

  • Bushing Length

    0.330 inches nominal

  • Auxiliary Switch Function And Quantity

    1 control

  • Special Features

    threaded bushing mounted

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Trip Release Characteristic

    time delay all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.625 inches nominal

  • Actuator Function

    trip-reset

  • Mounting Surface To Terminal End Distance

    1.828 inches maximum

  • Internal Trip Release Configuration

    series trip all locations

  • Body Length

    1.932 inches maximum

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...