NSN: 5925-00-168-1459
Circuit Breakers
CIRCUIT BREAKER
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Fragility Factor
moderately rugged
-
Special Handling Feature
magnetic
-
Circuit Protection Type
overcurrent all locations
-
Pole Quantity
2
-
Thread Series Designator
unc
-
Actuator Position Designation
at each pole
-
Reset Method
manual
-
Precious Material
silver
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay all locations
-
Actuator Function
trip-reset
-
Internal Trip Release Configuration
series trip all locations
-
Mounting Facility Type And Quantity
4 threaded hole
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.050 inches minimum and 2.070 inches maximum
-
Thread Quantity Per Inch
32
-
Trip Release Method
magnetic-hydraulic all locations
-
Unpackaged Unit Weight
0.547 pounds
-
Body Style
multipole-multiple actuator type
-
Boss Height
0.120 inches minimum and 0.140 inches maximum
-
Center To Center Distance Between Terminals Parallel To Width
0.720 inches minimum and 0.740 inches maximum
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations and 50.0 dc all locations
-
Body Width
1.520 inches minimum and 1.540 inches maximum
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations and 2000.0 dc all locations
-
Center To Center Distance Between Terminals Parallel To Length
1.930 inches minimum and 1.950 inches maximum
-
Maximum Continuous Load Current Rating Per Pole
35.0 amperes ac all locations and 35.0 amperes dc all locations
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.200 minimum at 200 pct all locations and 1.000 maximum at 200 pct all locations
-
Nominal Thread Size
0.138 inches
-
Frequency In Hertz
60.0 all locations
-
Main Contact Tripping Mechanism Type
trip free
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
-
Body Length
2.520 inches minimum and 2.540 inches maximum
-
Arc Quenching Method
magnetic blowout
-
Precious Material And Location
contact surfaces silver
-
Inclosure Protection Type For Which Designed
explosion proof and shock resistant
-
Manual Actuator Type And Quantity
2 toggle
-
Thread Pitch Diameters
+0.1177/+0.1214 inches
-
Terminal Type And Quantity
4 threaded stud
-
Mounting Surface To Terminal End Distance
2.430 inches minimum and 2.570 inches maximum
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.720 inches minimum and 0.740 inches maximum
-
External Actuator Linkage Arrangement
one and two linked
-
Case Material
plastic