NSN: 5925-00-172-4866

Circuit Breakers

CIRCUIT BREAKER

5925 - Circuit Breakers

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip all locations

  • Switch Voltage Rating And Type In Volts

    125.0 ac and 50.0 dc

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic all locations

  • Body Style

    multipole-multiple actuator type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Switch Contact Arrangement

    single pole, double throw

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Special Features

    voltage protection barriers between poles

  • Nominal Thread Size

    0.138 inches

  • Body Height

    4.000 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Center To Center Distance Between Terminals Parallel To Length

    3.550 inches nominal

  • Arc Quenching Method

    magnetic blowout

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    2.052 inches nominal

  • Precious Material And Location

    contact surfaces silver

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Mounting Surface To Terminal End Distance

    4.000 inches nominal

  • Boss Height

    0.219 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    2.052 inches nominal

  • Frequency In Hertz

    47.0 all locations or 63.0 all locations

  • Mounting Facility Type And Quantity

    6 threaded stud

  • Body Length

    4.750 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    480.0 ac all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Manual Actuator Type And Quantity

    3 toggle

  • Unpackaged Unit Weight

    2.000 pounds

  • Trip Delay Time In Seconds Per Rated Continuous Current

    40.000 minimum at 200 pct all locations and 100.000 maximum at 200 pct all locations

  • Case Material

    plastic

  • Terminal Type And Quantity

    6 threaded stud

  • Switch Location And Position Designation

    internal at pole one and internal at pole three

  • Fragility Factor

    moderately rugged

  • Switch Terminal Type

    tab, solder lug

  • Special Handling Feature

    magnetic

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Body Width

    4.750 inches nominal

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Auxiliary Switch Function And Quantity

    2 alarm

  • Maximum Continuous Load Current Rating Per Pole

    600.0 milliamperes ac all locations

  • Precious Material

    silver

  • Storage Type

    general purpose warehouse

  • Switch Current Rating And Type In Amps

    5.0 ac and 1.0 dc

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.